2-line filters
B84142A*S002 … S018
for converters in traction systems
Technical data and measuring conditions
Rated voltage VR
Type S002: 750 V DC
Type S003: 1000 V DC
Type S018: 2000 V DC
Rated current IR
Test voltage Vtest
Referred to 60 °C ambient temperature
Type S002: 2000 V DC, 60 s (L+/L–)
4900 V DC, 60 s (L+ || L–/case)
6000 V DC, 2 s (L+ || L–/case)
Type S003: 2500 V DC, 60 s (L+/L–)
4900 V DC, 60 s (L+ || L–/case)
6000 V DC, 2 s (L+ || L–/case)
Type S018: 4000 V DC, 60 s (L+/L–)
4900 V DC, 60 s (L+ || L–/case)
6000 V DC, 2 s (L+ || L–/case)
Overload capability (thermal)
1.6 · IR for 20 s per hour or
2.0 · IR for 10 s per hour
Climatic category (IEC 60068-1)
40/100/21 (–40 °C/+100 °C/21 days damp heat test)
Characteristics and ordering codes
VR
DC
V
IR
A
Rtyp
Approx.
weight
kg
Ordering code
µΩ
250
63
57
33
63
57
33
63
57
33
12
13
26
12
13
26
12
13
26
B84142A0250S002
B84142A0500S002
B84142A1000S002
B84142A0250S003
B84142A0500S003
B84142A1000S003
B84142A0250S018
B84142A0500S018
B84142A1000S018
750
500
1000
250
1000
2000
500
1000
250
500
1000
Please read Cautions and warnings and
Important notes at the end of this document.
3
01/06