RF chokes
BC series
B78108S
B78148S
General technical data
Rated inductance LR
Measuring frequency: L ≤ 10 μH
=
1 MHz
10 μH < L ≤ 4700 μH = 100 kHz
L > 4700 μH
≤ 1 mA
= 10 kHz
Measuring current:
Distance between
measuring clamps:
25.4 mm
Q factor Qmin
Measured with HP 4342A
Rated current IR
Maximum permissible DC current
referred to 40 °C ambient temperature,
for derating see below
Inductance decrease ΔL/L0
DC resistance Rmax
Resonance frequency fres, min
Climatic category
≤10% (referred to initial value) at IR
at 20 °C ambient temperature
Measured at 20 °C ambient temperature,
distance between measuring clamps: 25.4 mm
Measured with Scalar Network Analyzer ZAS
from Rohde & Schwarz
55/125/56 (–55 °C/+125 °C/56 days damp heat test)
to IEC 60068-1
Solderability
235 °C, 2 s, ≥90% wetting
to IEC 60068-2–20, test Ta
Resistance to soldering heat
Tensile strength of leads
RoHS-compatible
To IEC 60068-2-20, test Tb 260 °C, 10 s
To IEC 60068-2-21, test Ua ≥20 N
RoHS-compatible is defined as compatible with the follow-
ing documents:
DIRECTIVE 2002/95/EC OF THE EUROPEAN PARLIA-
MENT AND OF THE COUNCIL of 13 February 2003 on the
restriction of the use of certain hazardous substances in
electrical and electronic equipment COM (2004) 606 final
Proposal for a COUNCIL DECISION amending Directive
2002/95/EC of the European Parliament and of the Council
for the purposes of establishing the maximum concentra-
tion values for certain hazardous substances in electrical
and electronic equipment.
Mounting information
When bending the leads, take care that the start-of-winding
areas at the face ends (protected by glue and
lacquer) are not subjected to any mechanical stress.
Please read the Important notes at the end of
this document.
6
11/05