Pressure sensors
B58601E32xxB709/711
AER xx.xx C32/4 F00 G08 N
Gauge pressure sensor die (open bridge, High TCR)
Operating pressures and ordering codes
Parameter @ 25 °C,
VDD = 5 V
Symbol
Typ.
Typ.
Typ.
Typ.
Typ.
Typ.
Typ.
Typ.
Units
Operating pressure4)
pr
1.6
2.5
4
6
10
16
25
40
bar
Temperature
–
TCV0
–20/–8/4
–9/–3/3
–12/0/12
–6/0/6
µV/V/K
coefficient
of offset (unglued) 11)
[min/typ/max]
+
TCV0
µV/V/K
% FS12)
Nonlinearity 14)
[typ/max]
Sensitivity 13)
[min/typ/max]
L
±0.2/±0.3
45/70/95 36/48/60 23/30/38 15/20/25 9/12/15
5.6/7.5/9.4 3.6/4.8/6 2.2/3/3.8
S
mV/bar
Min over pressure 5)
Min burst pressure 6)
pov
4
6.25
7.5
10
12
15
18
25
30
40
48
62.5
75
75
90
bar
bar
pburst
4.8
Product type
Ordering code
Delivery form on
tape
Ordering code
Delivery in tray
mbar
bar
0.001
Pa
kPa
Psi
Torr
mWS
0.0102
10.200
0.000102
1.02
Conversion table
mbar
bar
(hPa)
1
100
0.100
100
0.0145
14.500
0.000145
0.145
1
0.750
750
1000
0.010
10.000
68.9
1
100000
1
Pa
(N/m2)
0.00001
0.0100
0.0689
0.00133
0.0981
0.001
1
0.00750
7.50
51.7
1
kPa
Psi
1000
6895
133
(Lb/inch2)
(mmHg)
6.89
0.133
9.81
0.703
0.0136
1
Torr
mWS
1.33
0.0193
1.42
98.100
9807
73.6
TPS PRS SD PD
2021-03-08
Please read Cautions and warnings and
Page 4 of 10
Important notes at the end of this document.