Pressure sensors
B58601E32xxB709/711
AER xx.xx C32/4 F00 G08 N
Gauge pressure sensor die (open bridge, High TCR)
Technical data
Absolute maximum ratings
Parameter
Symbol
Conditions
Min.
Typ.
Max.
Unit
Supply voltage
Maximum supply soltage
Temperature ranges
Operating temperature range
VDD
Without damage 1)
10
V
2)
3)
Ta
–40
–50
–50
150
165
175
°C
°C
°C
Storage temperature range
Tst
For t <2 h
Pressure ranges
Operating pressure ranges
Over pressure
pr
Gauge pressure 4)
Gauge pressure 5)
Gauge pressure 6)
0 ... 1.6
0 ... 40
bar
pr
pov
See next table
See next table
Burst pressure
pburst
pr
Electrical specifications
Parameter
Symbol
Conditions
Min.
Typ.
Max.
Unit
Supply voltage / bridge resistance
Operating supply voltage
Total bridge resistance
7)
VDD
Rb
1.0
4.0
2.6
0
5.0
6.0
3.2
8
V
@ 25 °C 8)
5.0
2.9
5
k
10–3/K
10–6/K2
Rb
Rb
Temperature coefficient
of total bridge resistance
@ 25 °C 9)
Output signal @ VDD = 5 V
Offset
Vo
S
@ 25 °C 10)
@ 25 °C 13)
-30
30
mV
Sensitivity
See next table
See next table
See next table
–2.1
mV/bar
µV/V/K
µV/V/K
10–3/K
10–6/K2
% FS12)
TCVo+
TCVo-
S
Temperature coefficient
of offset
Unglued 11)
–2.5
0
–1.9
8
Temperature coefficient
of the sensitivity
@ 25 °C 15)
5
S
16)
Pressure hysteresis
pHys
–0.1
0.1
Long-term stability (Full scale normal output FSON = 120 mV)
17)
Temperature hysteresis of offset
Temperature cycle drift of offset
High temperature drift of offset
Long term stability of offset
THV0
TCDV0
HTDV0
LTSV0
–0.2
–0.1
±0.1
±0.05
±0.05
±0.1
0.2
0.1
% FSON
% FSON
% FSON
% FSON
17)
17)
17)
–0.15
–0.2
0.15
0.2
TPS PRS SD PD
2021-03-08
Please read Cautions and warnings and
Page 3 of 10
Important notes at the end of this document.