Pressure sensors
C32 series
B58601E32**B615/…B646
Gauge low pressure sensor die C32/1 (open bridge)
Operating pressures and ordering codes
Parameter @ 25 °C,
Symbol
Typ.
Typ.
Units
VDD = 5 V
Operating pressure 4)
pr
0.4
1.0
bar
–
TCV0
-20 / -8 / 4
-20 / -8 / 4
µV/V/K
Temperature coefficient
of offset11) [min/typ/max]
+
TCV0
-9 / -3 / 3
-9 / -3 / 3
µV/V/K
Sensitivity 13) [min/typ/max]
Nonlinearity 14) [typ/max]
Over pressure 5) [min]
S
L
160/215/270
±0.4/±0.7
1.0
130/160/190
±0.4/±0.7
2.5
mV/bar
% FS12)
bar
pov
Burst pressure 6) [min]
pburst
1.2
3
bar
Product type
Ordering code
Delivery form on tape
Ordering code
Delivery in tray
mbar
bar
Pa
kPa
Psi
Torr
mWS
Conversion table
mbar
bar
(hPa)
1
0.001
1
100
100000
1
0.100
100
0.0145
0.750
750
0.0102
10.200
0.000102
1.02
1000
0.010
10.000
68.9
14.500
0.000145
0.145
1
Pa
(N/m2)
0.00001
0.0100
0.0689
0.00133
0.0981
0.001
1
0.00750
7.50
51.7
1
kPa
Psi
1000
6895
133
(Lb/inch2)
6.89
0.133
9.81
0.703
0.0136
1
Torr
mWS
1.33
0.0193
1.42
98.100
9807
73.6
TPS PRS SD PD
2021-03-08
Please read Cautions and warnings and
Page 4 of 10
Important notes at the end of this document.