5秒后页面跳转
B3104UALTP PDF预览

B3104UALTP

更新时间: 2024-01-24 20:12:45
品牌 Logo 应用领域
力特 - LITTELFUSE /
页数 文件大小 规格书
4页 1139K
描述
Trigger Device

B3104UALTP 技术参数

是否Rohs认证: 符合生命周期:Active
包装说明:,Reach Compliance Code:unknown
风险等级:5.62Base Number Matches:1

B3104UALTP 数据手册

 浏览型号B3104UALTP的Datasheet PDF文件第1页浏览型号B3104UALTP的Datasheet PDF文件第3页浏览型号B3104UALTP的Datasheet PDF文件第4页 
SIDACtor® ProtectionThyristors  
SLIC Protection  
Surge Ratings  
IPP  
ITSM  
50/60 Hz  
0.2/310 1  
0.5/700 2  
2/10 1  
2/10 2  
8/20 1  
10/160 1  
10/160 2  
10/560 1  
10/560 2  
5/320 1  
9/720 2  
10/360 1  
10/360 2  
10/1000 1  
10/1000 2  
5/310 1  
di/dt  
1.2/50 2  
10/700 2  
A min  
A min  
A min  
A min  
A min  
A min  
A min  
A min  
A min  
A min  
A/µs max  
C
50  
500  
400  
200  
150  
200  
175  
100  
200  
50  
500  
Notes:  
- Peak pulse current rating (IPP) is repetitive and guaranteed for the life of the product that remains in thermal equilibrium.  
- IPP ratings applicable over temperature range of -40ºC to +85ºC (IPP rating assumes ±REF equals +/- 48 ±)  
- The component must initially be in thermal equilibrium with -40°C < TJ < +150°C  
1 Current waveform in µs  
2 ±oltage waveform in µs  
Thermal Considerations  
Package  
Symbol  
Parameter  
Value  
Unit  
Modified MS-013  
TJ  
Operating JunctionTemperature Range  
-40 to +125  
°C  
6
5
4
TS  
StorageTemperature Range  
-65 to +150  
60  
°C  
1
2
3
R0JA  
Thermal Resistance: Junction to Ambient  
°C/W  
V-I Characteristics  
tr x td PulseWaveform  
+I  
IPP  
VDRM  
VS  
tr = rise time to peak value  
td = decay time to half value  
Peak  
Value  
100  
IH  
VREF  
VS  
-VREF  
VDRM  
IS  
Waveform = tr x td  
VT  
IDRM  
+V  
50  
0
-V  
Half Value  
IDRM  
IH  
IS  
IT  
tr  
td  
0
IPP  
t – Time (µs)  
-I  
NormalizedVS Change vs. JunctionTemperature  
Normalized DC Holding Current vs. CaseTemperature  
2.0  
1.8  
1.6  
1.4  
14  
12  
10  
8
6
25°C  
25 °C  
1.2  
4
2
0
1.0  
0.8  
0.6  
0.4  
-4  
-6  
-8  
-40 -20  
0
20 40 60  
80 100 120 140 160  
-40 -20  
0
20 40 60 80 100 120 140 160  
JunctionTemperature (TJ) – °C  
CaseTemperature (TC) - ºC  
© 2017 Littelfuse, Inc.  
Specifications are subject to change without notice.  
Revised: 02/23/17  

与B3104UALTP相关器件

型号 品牌 描述 获取价格 数据表
B3104UARP LITTELFUSE BATTRAX PROTECT DUAL 150A MS-013

获取价格

B3104UATP LITTELFUSE BATTRAX DUAL POS/NEG 150A MS-013

获取价格

B3104UC LITTELFUSE 本Battrax®器件可为使用正、负环电压的SLIC提供保护。 它可对上升时间为100 V

获取价格

B3104UCL LITTELFUSE Single Port Positive/Negative SLIC Protector

获取价格

B3104UCLRP LITTELFUSE Silicon Surge Protector, 210V V(BO) Max, 50A, MODIFIED MS-013, 6 PIN

获取价格

B3104UCLTP LITTELFUSE Silicon Surge Protector, 210V V(BO) Max, 50A, MODIFIED MS-013, 6 PIN

获取价格