4.0-11.0 GHz GaAs MMIC

B1007-BD 数据手册

 浏览型号B1007-BD的Datasheet PDF文件第3页浏览型号B1007-BD的Datasheet PDF文件第4页浏览型号B1007-BD的Datasheet PDF文件第5页浏览型号B1007-BD的Datasheet PDF文件第6页浏览型号B1007-BD的Datasheet PDF文件第7页浏览型号B1007-BD的Datasheet PDF文件第8页 
4.0-11.0 GHz GaAs MMIC  
Buffer Amplifier  
October 2009 - Rev 10-Oct-09  
B1007-BD  
Handling and Assembly Information  
CAUTION! - Mimix Broadband MMIC Products contain gallium arsenide (GaAs) which can be hazardous to the human body  
and the environment. For safety, observe the following procedures:  
• Do not ingest.  
• Do not alter the form of this product into a gas, powder, or liquid through burning, crushing, or chemical  
processing as these by-products are dangerous to the human body if inhaled, ingested, or swallowed.  
• Observe government laws and company regulations when discarding this product.This product must be  
discarded in accordance with methods specified by applicable hazardous waste procedures.  
Life Support Policy - Mimix Broadband's products are not authorized for use as critical components in life support devices or  
systems without the express written approval of the President and General Counsel of Mimix Broadband. As used herein: (1)  
Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body, or (b)  
support or sustain life, and whose failure to perform when properly used in accordance with instructions for use provided in  
the labeling, can be reasonably expected to result in a significant injury to the user. (2) A critical component is any component  
of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support  
device or system, or to affect its safety or effectiveness.  
ESD - Gallium Arsenide (GaAs) devices are susceptible to electrostatic and mechanical damage. Die are supplied in antistatic  
containers, which should be opened in cleanroom conditions at an appropriately grounded anti-static workstation. Devices  
need careful handling using correctly designed collets, vacuum pickups or, with care, sharp tweezers.  
Die Attachment - GaAs Products from Mimix Broadband are 0.100 mm (0.004") thick and have vias through to the backside to  
enable grounding to the circuit. Microstrip substrates should be brought as close to the die as possible.The mounting surface  
should be clean and flat. If using conductive epoxy, recommended epoxies are Tanaka TS3332LD, Die Mat DM6030HK or  
DM6030HK-Pt cured in a nitrogen atmosphere per manufacturer's cure schedule. Apply epoxy sparingly to avoid getting any  
on to the top surface of the die. An epoxy fillet should be visible around the total die periphery. For additional information  
please see the Mimix "Epoxy Specifications for Bare Die" application note. If eutectic mounting is preferred, then a fluxless  
gold-tin (AuSn) preform, approximately 0.001 thick, placed between the die and the attachment surface should be used. A die  
bonder that utilizes a heated collet and provides scrubbing action to ensure total wetting to prevent void formation in a  
nitrogen atmosphere is recommended.The gold-tin eutectic (80% Au 20% Sn) has a melting point of approximately 280 ºC  
(Note: Gold Germanium should be avoided).The work station temperature should be 310 ºC +/- 10 ºC. Exposure to these  
extreme temperatures should be kept to minimum.The collet should be heated, and the die pre-heated to avoid excessive  
thermal shock. Avoidance of air bridges and force impact are critical during placement.  
Wire Bonding - Windows in the surface passivation above the bond pads are provided to allow wire bonding to the die's gold  
bond pads.The recommended wire bonding procedure uses 0.076 mm x 0.013 mm (0.003" x 0.0005") 99.99% pure gold ribbon  
with 0.5-2% elongation to minimize RF port bond inductance. Gold 0.025 mm (0.001") diameter wedge or ball bonds are  
acceptable for DC Bias connections. Aluminum wire should be avoided.Thermo-compression bonding is recommended  
though thermosonic bonding may be used providing the ultrasonic content of the bond is minimized. Bond force, time and  
ultrasonics are all critical parameters. Bonds should be made from the bond pads on the die to the package or substrate. All  
bonds should be as short as possible.  
Ordering Information  
Part Number for Ordering  
XB1007-BD-000V  
Description  
Where“V”is RoHS compliant die packed in vacuum release gel paks  
XB1007-BD-EV1  
XB1007 die evaluation module  
Caution: ESD Sensitive  
Appropriate precautions in handling, packaging  
and testing devices must be observed.  
Proper ESD procedures should be followed when handling this device.  
Page 9 of 9  
Mimix Broadband, Inc., 10795 Rockley Rd., Houston,Texas 77099  
Tel: 281.988.4600 Fax: 281.988.4615 mimixbroadband.com  
Characteristic Data and Specifications are subject to change without notice. ©2009 Mimix Broadband, Inc.  
Export of this item may require appropriate export licensing from the U.S. Government. In purchasing these parts, U.S. Domestic customers accept  
their obligation to be compliant with U.S. Export Laws.  

与B1007-BD相关器件

型号 品牌 描述 获取价格 数据表
B1007-BD_09 MIMIX 4.0-11.0 GHz GaAs MMIC

获取价格

B1007RW MPD Compact 1 x 2 Inch 10W Wide Input Range DC/DC Converters

获取价格

B1008RW MPD Compact 1 x 2 Inch 10W Wide Input Range DC/DC Converters

获取价格

B100NA20X4 ANAREN Chip Attenuator 100 Watts, 20 dB

获取价格

B100NA30X4 ANAREN Chip Attenuator 100 Watts, 30 dB

获取价格

B100NF03L STMICROELECTRONICS N-channel 30V - 0.0026ohm - 100A - D2PAK/I2/TO-220 STripFET TM III Power MOSFET

获取价格