Model Selection Guide
Input
Current (mA)
Output
Fuse Rating
Slow-Blow
(mA)
Voltage (VDC)
Model
Reflected
Ripple
Efficiency
(%, Typ)
Voltage Current
(VDC) (mA, Max) (mA, Min)
Current
Number
Nominal
Range
Full-Load No-Load
Current
(mA, Typ)
B1001R
B1002R
B1003R
5
5
5
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
2,500
2,538
2,669
30
30
60
>50
>50
>50
78
78
75
5,000
5,000
5,000
!12.0
!15.0
!18.0
!415
!330
!278
!42
!33
!28
Notes:
1. Transient recovery is measured to within a 1% error band for a load step change of 75% to 100%.
2. When measuring output ripple, it is recommended that an external 0.47 µF ceramic capacitor be placed from each output (pin 3 &
pin 5) to common (pin 4).
3. Dual output units may be connected to provide a 24 VDC, 30 VDC or 36 VDC output. To do this, connect the load across the posi-
tive (+Vout) and negative (-Vout) outputs and float the output common.
Derating Curve
100
80
60
40
20
0
-40 -20
0
5
15 25 35 45 55 65 75 85 95 105
Ambient Temperature ( C)
Mechanical Dimensions
Bottom
Capacitive Load
0.40
(10.2)
5
4
3
0.40
(10.2)
µF Max
2
1
1.00
(25.4)
!1,000
0.40
(10.2)
0.40
(10.2)
Pin Connections
0.10
(2.54)
Pin
1
Function
+Vin
0.80
(20.3)
0.60
(15.2)
2
-Vin
3
+Vout
Common
-Vout
4
2.00
(50.8)
5
0.40
(10.2)
Side
0.24
(6.0)
Notes:
All dimensions are typical in inches (mm)
0.04 Dia
(1.0)
Tolerance x.xx = !0.01 (!0.25)
232 Tosca Drive, Stoughton, MA 02072
www.micropowerdirect.com
MicroPower