AZ2100
UL/CUR File E44211 Approved Contact Ratings
Form A Form B
Form C
Load Type
Cycles
Volts
(NO)
(NC)
NO
NC
General Purpose
(Inductive)
Resistive
100,000
30,000
100,000
100,000
100,000
100,000 *
6,000
125 or 240 VAC
277 VAC
125 or 240 VAC
30 VDC
277 VAC
240 VAC
250 VAC
125, 240 or
277 VAC
30 A
30 A
30 A
20 A
20 A
15 A
40 A
6 A
15 A
30 A
15 A
10 A
—
—
—
3 A
30 A
30 A
—
20 A
—
—
40 A
6 A
15 A
30 A
—
10 A
—
—
—
3 A
Maximum Switching Capacity
40
30
NO
NC
Ballast
6,000
20
6,000
6,000
30,000
100,000
6,000
100,000
6,000
6,000***
30,000
100,000
30,000 **
277 VAC
125 VAC
125 VAC
125 VAC
240 VAC
277 VAC
125 VAC
240 VAC
20 A
800 VA
800 VA
690 VA
1152 VA
764 VA
1 HP
—
290 VA
—
—
768 VA
—
1/4 HP
1 HP
—
—
—
—
—
Pilot Duty
800 VA 290 VA
690 VA
470 VA 275 VA
1152 VA 768 VA
764 VA
1 HP
2 HP
—
10
8
—
1/4 HP
1 HP
—
—
—
AC RESISTIVE
LOAD
6
5
Motor Load
3 HP
1 HP
125 VAC
1 HP
3/4 HP
4
125 or 277 VAC
120 VAC
3/4 HP
82.8 LRA
13.8 FLA
96 LRA
30 FLA
60 LRA
20 FLA
82.8 LRA
27 FLA
80 LRA
30 FLA
41.4 LRA
6.9 FLA
60 LRA
20 FLA
15A
DC RESISTIVE
LOAD
3
2
Definite Purpose
82.8 LRA
13.8 FLA
60 LRA 33 LRA
20 FLA 10 FLA
60 LRA 30 LRA
20 FLA 12 FLA
82.8 LRA
27 FLA
60 LRA 33 LRA
20 FLA 10 FLA
41.4 LRA
6.9 FLA
60 LRA
20 FLA
15A
—
—
30,000
30,000 **
100,000
30,000
125 VAC
125 VAC
125 VAC
240 VAC
240 VAC
277 VAC
33 LRA
10 FLA
30 LRA
12 FLA
—
1
10
20
30
40
60
80 100
200 300
(LRA-Locked Rotor)
(FLA-Full Load)
—
—
VOLTAGE
—
33 LRA
10 FLA
—
—
—
—
—
—
3A
30,000 **
100,000
—
—
—
—
3A
3A
—
—
TV–3
TV–3
Tungsten
6,000
6,000
6,000
6,000
25,000
25,000
125 VAC
240 VAC
120 VAC
240 VAC
120 VAC
120 VAC
Coil Temperature Rise
5A
—
—
TV–5
5A
—
—
TV–5
—
180
3A
—
TV–3
160
140
120
100
TV–5
TV–3
—
* Ambient temperature 96°C (208°F) max. sealed and 105°C (221°F) unsealed.
** Ambient temperature 85°C (185°F) max. sealed and unsealed.
*** Ambient temperature 65°C (149°F) max. sealed and unsealed.
80
30A
60
25A
40
20A
15A
0A
20
0
40ꢀ
60ꢀ
80ꢀ
100ꢀ 120ꢀ
140ꢀ 160ꢀ 180ꢀ 200ꢀ
Percent of Nominal Coil Voltage (at 20˚C)
4/1/14