Limit Alarms (potentiometer adj.) A-UNIT

ATG-1111-R 数据手册

 浏览型号ATG-1111-R的Datasheet PDF文件第1页浏览型号ATG-1111-R的Datasheet PDF文件第3页浏览型号ATG-1111-R的Datasheet PDF文件第4页 
MODEL: B3FP  
Detecting level: See the table below  
Two-wire Current Pulse  
Max. 55°C (131°F) for UL approval  
Operating humidity: 0 to 95 %RH (non-condensing)  
Mounting: DIN rail  
Input resistance: Receiving resistor 200 Ω  
Input range: 0 – 25 mA  
Weight: 80 g (2.8 oz)  
Detecting level: See the table below  
(Convert current into voltage using the receiving resistor  
value.)  
PERFORMANCE in percentage of span  
Accuracy: ±0.1 % (±0.3 % for frequencies below 10 Hz for  
sine waves detected with capacitor coupling)  
Temp. coefficient: ±0.02 %/°C (±0.01 %/°F)  
Response time: Max. 0.5 sec. + 1 pulse cycle (0 – 90 %)  
Insulation resistance: ≥ 100 MΩ with 500 V DC  
Dielectric strength: 2000 V AC @1 minute  
PULSE AMPLITUDE  
DETECTING LEVEL  
0.1 – 2 Vp-p 2 – 10 Vp-p 10 – 200 Vp-p  
Zero-cross  
Low level  
0V  
45mV  
200mV  
1V  
0V  
60mV  
0V  
300mV  
2V  
Middle level  
High level  
400mV  
2V  
10V  
(input to output to ground)  
DETECTING LEVEL  
Zero-cross  
DEADBAND  
15ꢀ of Amplitude, ≥45mV*  
15ꢀ of Amplitude, ≥40mV*  
15ꢀ of Amplitude, ≥80mV*  
40ꢀ of Detecting Level  
STANDARDS & APPROVALS  
EU conformity:  
Low level  
Middle level  
High level  
EMC Directive  
EMI EN 61000-6-4  
*Minimum deadband required for the amplitude 0.1 – 2 Vp-p.  
EMS EN 61000-6-2  
VOLTAGE PULSE WAVEFORM  
RoHS Directive  
Volts  
100V max.  
Approval:  
VH  
VL  
UL/C-UL general safety requirements  
(UL 61010-1, CAN/CSA-C22.2 No.1010-1)  
Amplitude  
Vinp-p  
DC Offset Detecting Level  
t
OUTPUT SPECIFICATIONS  
Output: 4 – 20 mA DC  
Load resistance vs. supply voltage:  
Load Resistance (Ω) = (Supply Voltage (V) – 12 (V)) ÷ 0.02  
(A) (including leadwire resistance)  
1650  
1600  
1400  
1200  
1000  
800  
600  
400  
200  
0
1012  
20  
30  
40 45  
SUPPLY VOLTAGE [V ]  
(600Ω maximum at 24V DC)  
INSTALLATION  
Supply voltage: 12 – 45 V DC  
Operating temperature:  
-40 to +85°C (-40 to +185°F)  
B3FP SPECIFICATIONS  
ES-7516 Rev.9 Page 2/4  
https://www.m-system.co.jp/  

与ATG-1111-R相关器件

型号 品牌 描述 获取价格 数据表
ATG-1111-R/Q MSYSTEM Limit Alarms (potentiometer adj.) A-UNIT

获取价格

ATG-1111-S MSYSTEM Limit Alarms (potentiometer adj.) A-UNIT

获取价格

ATG-1111-S/Q MSYSTEM Limit Alarms (potentiometer adj.) A-UNIT

获取价格

ATG-1111-V MSYSTEM Limit Alarms (potentiometer adj.) A-UNIT

获取价格

ATG-1111-V/Q MSYSTEM Limit Alarms (potentiometer adj.) A-UNIT

获取价格

ATG-1112-B MSYSTEM Limit Alarms (potentiometer adj.) A-UNIT

获取价格