ATA6620  
4.3  
Sleep Mode  
A falling edge at EN while TXD is low switches the IC into Sleep mode. The TXD Signal has to  
be logic low during the Mode Select window (Figure 4-4 on page 8). We recommend using the  
same microcontroller port for EN as for TXD; in this case the mode change is only one  
command.  
In Sleep mode the transmission path is disabled. Supply current from VBatt is typically  
IVSsleep = 10 µA. The VCC regulator is switched off; NRES and RXD are low. The internal slave  
termination between pin LIN and pin VS is disabled to minimize the power dissipation in case pin  
LIN is short-circuited to GND. Only a weak pull-up current (typically 10 µA) between pin LIN and  
pin VS is present.  
A falling edge at pin LIN followed by a dominant bus level maintained for a certain time period  
(Tbus) results in a remote wake-up request. The device switches from Sleep mode to Pre-normal  
mode. The VCC regulator is activated and the internal LIN slave termination resistor is switched  
on. The remote wake-up request is indicated by a low level at pin RXD to interrupt the microcon-  
troller (Figure 4-5 on page 8).  
With EN high you can switch directly from Silent to Normal mode. In the application where the  
ATA6620 supplies the microcontroller, the wake-up from Sleep mode is only possible via pin  
LIN.  
4.4  
4.5  
Pre-normal Mode  
At system power-up the device automatically switches to Pre-normal mode. The voltage regula-  
tor is switched on (VCC = 5V/50 mA) (see Figure 4-6 on page 9) after typically tVCC > 300 µs. The  
NRES output switches to low for tres = 10 ms and sends a reset to the microcontroller. LIN com-  
munication is switched off, and the undervoltage detection is active.  
A power-down of VBatt (VS < 4.15V) during Silent or Sleep mode switches into Pre-normal mode  
after powering up the IC.  
Unpowered Mode  
If battery voltage is connected to the application circuit (Figure 4-6 on page 9), the voltage at the  
VS pin increases due to the block capacitor. When VS is higher than the VS undervoltage thresh-  
old, VSth, the IC-mode changes from Unpowered to Pre-normal mode. The VCC output voltage  
reaches nominal value after tVCC. This time depends on the VCC capacitor and the load.  
NRES is low for the reset time delay tReset; no mode change is possible during this time.  
7
4850D–AUTO–02/06  

与ATA6620_06相关器件

型号 品牌 描述 获取价格 数据表
ATA6620N ATMEL LIN Bus Transceiver with Integrated Voltage Regulator

获取价格

ATA6620N_09 ATMEL LIN Bus Transceiver with Integrated Voltage Regulator

获取价格

ATA6620N-TAQY ATMEL LIN Bus Transceiver with Integrated Voltage Regulator

获取价格

ATA6620-TAQY ATMEL LIN ABUS TRANSCEIVER WITH INTEGRATED VOLTAGE REGULATOR

获取价格

ATA6621 ATMEL LIN Transceiver with 5V Regulator and Watchdog

获取价格

ATA6621_06 ATMEL LIN Transceiver with 5V Regulator and Watchdog

获取价格