ASSR-601JV, ASSR-601JT
Data Sheet
Electrical Specifications (DC)
Unless otherwise stated, all minimum/maximum specifications are over recommended operating conditions. All typical values are
at T = 25°C, I = 10 mA.
A
F
Parameter
Symbol
VR
Device
Min.
5
Typ.
—
Max.
—
Unit
Test Conditions
IR =10 μA
Fig.
Note
Input Reverse Breakdown Voltage
Input Forward Voltage
V
V
V
VF
1.25
1.55
1.85
—
IF = 10 mA
1
3
4
4
7
8
8
a, b
a
Output Withstand Voltage
Output Leakage Current
|VO(OFF)
|
1500 1700
IO = 250 μA, TA = 25°C
IO(OFF)
ASSR-601JV
ASSR-601JT
—
—
—
—
—
0.3
0.3
1000
5000
—
nA VO = 1000V
a
nA VO = 1000V
a
Output Capacitance
Output Resistance
COUT
RON
190
100
100
pF VO = 0V, f = 1 MHz
300
250
Ω
Ω
IO = 2 mA
IO = 10 mA
a.
Device is in OFF state with VF ≤ 0.4V.
b. Per AEC-Q101, device performance is demonstrated with high temperature reverse bias stress at 1200V (80% of rated voltage).
Switching Specifications (AC)
Unless otherwise stated, all minimum/maximum specifications are over recommended operating conditions. All typical values are
at T = 25°C, I = 10 mA.
A
F
Parameter
Symbol
Min.
—
Typ.
0.8
Max.
4.0
Unit
ms
Test Conditions
Fig.
Note
Turn-On Time
TON
IF = 10 mA, VDD = 40V, RLOAD = 20 kΩ
IF = 30 mA, VDD = 40V, RLOAD = 20 kΩ
VDD = 40V, RLOAD = 20 kΩ
9, 11, 13
—
0.3
1.0
ms
Turn-Off Time
TOFF
—
0.05
0.5
ms
10, 12, 13
Package Characteristics
Unless otherwise stated, all minimum/maximum specifications are over recommended operating conditions. All typical values are
at T = 25°C.
A
Parameter
Symbol
Min.
Typ.
Max.
Unit
Test Conditions
Fig.
Note
b, c
Input-Output Momentary Withstand
Voltagea
VISO
5000
—
—
VRMS RH ≤ 50%, tm = 1 minute;
TA = 25°C
b
b
109
—
1014
0.6
Input-Output Resistance
Input-Output Capacitance
RI-O
CI-O
—
—
Ω
VI-O = 1000 VDC
pF
f = 1 MHz; VI-O = 0 VDC
a.
The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output continuous voltage rating.
b. Device considered a two-terminal device: pins 1 to 8 shorted together, and pins 9, 10, 15, and 16 shorted together.
c.
In accordance with UL 1577, each optocoupler is proof tested by applying an insulation test voltage ≥ 6000 VRMS for 1 second.
Broadcom