ASSR-601JV, ASSR-601JT
Data Sheet
Regulatory Information
The ASSR-601JV and ASSR-601JT are approved by the following organizations:
UL/cUL
IEC/EN/DIN EN 60747-5-5
UL 1577, component recognition program up to VISO = 5 kVRMS
Approved under CSA Component Acceptance Notice #5.
IEC 60747-5-5
EN 60747-5-5
DIN EN 60747-5-5
Insulation and Safety Related Specifications
Parameter
Symbol
ASSR-601JV/JT
Unit
Conditions
Minimum External Air Gap (Clearance)
L(101)
8.3
8.3
0.5
mm
Measured from input terminals to output terminals,
shortest distance through air.
Minimum External Tracking (Creepage)
L(102)
mm
mm
Measured from input terminals to output terminals,
shortest distance path along body.
Minimum Internal Plastic Gap (Internal
Clearance)
Through insulation distance conductor to conductor,
usually the straight line distance thickness between
the emitter and detector.
Tracking Resistance (Comparative
Tracking Index)
CTI
>600
V
IEC 60695.
IEC/EN/DIN EN 60747-5-5 Insulation Related Characteristic
Description
Symbol
Characteristic
Unit
Installation classification per DIN VDE 0110/1.89, Table 1
For rated mains voltage < 600 VRMS
I - III
I - II
For rated mains voltage < 1000 VRMS
Climatic Classification
40/125/21
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
2
VIORM
VPR
1414
VPEAK
VPEAK
Input to Output Test Voltage, Method b
VIORM x 1.875 = VPR, 100% Production Test with tm = 1 sec
2651
2262
6000
Partial Discharge < 5 pC
Input to Output Test Voltage, Method a
VIORM x 1.6 = VPR, Type and sample test, tm = 10 sec,
VPR
VPEAK
Partial Discharge < 5 pC
Highest Allowable Overvoltage
VIOTM
VPEAK
(Transient Overvoltage, tini = 60 sec)
Safety Limiting Values
(Maximum values allowed in the event of a failure)
Ambient Safety Temperature
Input Current
TS
175
400
1200
°C
mA
mW
IS,INPUT
PS,OUTPUT
Output Power
>109
Insulation Resistance at TS, VIO = 500V
RS
Ω
Broadcom