MODEL: AS4V  
Plug-in Signal Conditioners M-UNIT  
[2] OUTPUT  
2: 4 points; N.O. or make contact  
3: 4 points; N.C. or break contact  
DC ALARM  
(dual or quad alarm trip; field-configurable)  
5: 2 points; SPDT or transfer contact  
2A: 4 points; N.O. or make contact (small load current)  
(CE not available. Option /UL Not selectable.)  
3A: 4 points; N.C. or break contact (small load current)  
(CE not available. Option /UL Not selectable.)  
5A: 2 points; SPDT or transfer contact (small load current)  
(CE not available. Option /UL Not selectable.)  
Functions & Features  
• Provides relay outputs at preset DC input levels  
• Quad or dual trip  
• Setting and display in engineering unit values  
• Setpoint adjustments with the front keypad  
• Software lock  
• Adjustable hysteresis (deadband)  
• On-delay timer  
[3] POWER INPUT  
• Hi/Lo trip and energized/de-energized coil independently  
selectable for each setpoint  
AC Power  
M2: 100 – 240 V AC, 50 – 60 Hz  
(Operational voltage range 85 – 264 V, 47 – 66 Hz)  
DC Power  
• Enclosed relays  
• Relays can be powered by 200 V AC and 100 V DC  
• High-density mounting on DIN rail  
R: 24 V DC  
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)  
P: 110 V DC  
Typical Applications  
• Annunciator  
(Operational voltage range 85 – 150 V, ripple 10 %p-p max.)  
• Various alarm applications  
[4] OPTIONS (multiple selections)  
Standards & Approvals  
50  
(1.97)  
blank: CE marking  
/UL: UL approval, CE marking  
Other Options  
80  
(3.15)  
blank: none  
/Q: Option other than the above (specify the specification)  
132  
(5.20)  
mm (inch)  
SPECIFICATIONS OF OPTION: Q (multiple selections)  
COATING (For the detail, refer to M-System's web site.)  
/C01: Silicone coating  
MODEL: AS4V–[1][2]–[3][4]  
/C02: Polyurethane coating  
/C03: Rubber coating (UL not available)  
TERMINAL SCREW MATERIAL  
ORDERING INFORMATION  
• Code number: AS4V-[1][2]-[3][4]  
Specify a code from below for each of [1] through [4].  
(e.g. AS4V-S22-R/UL/Q)  
/S01: Stainless steel (UL not available)  
EX-FACTORY SETTING  
/SET: Preset according to the Ordering Information Sheet  
(No. ESU-1609)  
• Specify the specification for option code /Q  
(e.g. /C01/SET)  
GENERAL SPECIFICATIONS  
Construction: Plug-in  
[1] INPUT  
Connection: M3.5 screw terminals  
Screw terminal: Chromated steel (standard) or stainless  
steel  
Current  
Z1: Range 0 – 50 mA DC (Input resistance 100 Ω)  
Voltage  
Housing material: Flame-resistant resin (black)  
Isolation: Input to output to power  
Sampling cycle: 100 msec.  
S1: Range -1 – +1 V DC (Input resistance 1 MΩ min.)  
S2: Range -10 – +10 V DC (Input resistance 1 MΩ min.)  
User-configurable items: Front key pad  
• Alarm setpoint  
AS4V SPECIFICATIONS  
ES-1609 Rev.20 Page 1/5  
https://www.m-system.co.jp/  

与AS4V-3-R相关器件

型号 品牌 获取价格 描述 数据表
AS4V-3-R/Q MSYSTEM

获取价格

Plug-in Signal Conditioners M-UNIT
AS4V-3-R/UL MSYSTEM

获取价格

Plug-in Signal Conditioners M-UNIT
AS4V-5A-M2 MSYSTEM

获取价格

Plug-in Signal Conditioners M-UNIT
AS4V-5A-M2/Q MSYSTEM

获取价格

Plug-in Signal Conditioners M-UNIT
AS4V-5A-M2/UL MSYSTEM

获取价格

Plug-in Signal Conditioners M-UNIT
AS4V-5A-P MSYSTEM

获取价格

Plug-in Signal Conditioners M-UNIT
AS4V-5A-P/Q MSYSTEM

获取价格

Plug-in Signal Conditioners M-UNIT
AS4V-5A-P/UL MSYSTEM

获取价格

Plug-in Signal Conditioners M-UNIT
AS4V-5A-R MSYSTEM

获取价格

Plug-in Signal Conditioners M-UNIT
AS4V-5A-R/Q MSYSTEM

获取价格

Plug-in Signal Conditioners M-UNIT