AQ-C
2. Characteristics
[Ambient temperature: 20°C 68°F; Input voltage ripple (output module) and output voltage ripple (input module): 1% or less]
1) Input module
Type
AC Input module
DC Input module
Remarks
Item
Operate time, max.
20 ms
20 ms
0.5 ms
0.5 ms
Input voltage: 24 V DC or 100V AC
Output voltage: 24 V DC
Output current: 25mA
Release time, max
Insulation resistance, min.
Breakdown voltage
109 Ω between input and output
at 500 V DC
2,500 Vrms between input and output
10 to 55Hz double amplitude of 3 mm
10 to 55Hz double amplitude of 3 mm
Min. 980 m/s2 {100 G}
For 1 minute
Destructive
Functional
Destructive
Functional
1 hour for X,Y, Z, axis
10 minutes for X,Y, Z, axis
5 time each for X,Y,Z axis
4 time each for X,Y,Z axis
Vibration
resistance
Shock
resistance
Min. 980 m/s2 {100 G}
Ambient temperature
Storage temperature
–30°C to +80°C –22°F to +176°F
–30°C to +100°C –22°F to +212°F
2) Output module
AC output
Zero-cross
Type
DC output
Remarks
Item
Random
1 ms
Operate time, max.
Release time, max.
1/2 cycle of voltage sine wave + 1ms
0.5 ms
1 ms
1/2 cycle of voltage sine wave + 1ms
109Ω between input and output
2,500 Vrms between input and output
10 to 55Hz double amplitude of 3 mm
10 to 55Hz double amplitude of 3 mm
Min. 980 m/s2 {100 G}
Insulation resistance, min.
Breakdown voltage
at 500 V DC
For 1 minute
Destructive
Functional
Destructive
Functional
1 hour for X,Y, Z, axis
10 minutes for X,Y, Z, axis
5 time each for X,Y,Z axis
4 time each for X,Y,Z axis
Vibration
resistance
Shock
resistance
Min. 980 m/s2 {100 G}
Ambient temperature
Storage temperature
–30°C to +80°C –22°F to +176°F
–30°C to +100°C –22°F to +212°F
Random Turn-ON,
Zero-cross (Turn-OFF)
Operational method
Zero-cross (Turn-ON and Turn-OFF)
—
REFERENCE DATA
1. Load current vs. ambient temperature
characteristics
2.-(1) Non-repetitive surge current vs. carrying
time characteristics
2.-(2) Non-repetitive surge current vs. carrying
time characteristics
(AC/DC output)
(AC output)
(DC output)
Use load current within range specified in the figure
below
1.0
0.8
0.6
0.4
5
4
3
2
1
0
30
20
10
0
0.2
0
–30
0
20
40
60
80
1
2
3
4 5 7 10
20 304050 70100
10
20 304050 70100 200 300
Carrying time, ms
1,000
Ambient temperature, °C
No. of cycles at 60 Hz
3. Input current vs. input voltage characteristics
(AC/DC output)
4.-(1) Input current vs. input voltage
characteristics
4.-(2) Input current vs. input voltage
characteristics
(AC input)
(DC input)
10
30
10
9
AC output
DC output
25
8
8
7
20
15
10
6
6
5
4
4
3
2
(5 V type)
(24 V type)
30
2
(12 V type)
5
0
1
0
0
100
200
300
0
10
20
5
10
15
20
25
30
35
Input voltage, V AC
Input voltage, V
Input voltage, V DC
ASCTB214E 201201-T1