AQ8
2) Random type
• 2 A type
Part No.
AQ2A2-C1-T5VDC
AQ2A2-C2-T5VDC
AQ2A2-C1-T12VDC
AQ2A2-C2-T12VDC
AQ2A2-C1-T24VDC
AQ2A2-C2-T24VDC
Remarks
Item
Rated voltage
5 V DC
4 to 6 V DC
Approx. 0.3 kΩ
Min. 0.5 V
12 V DC
9.6 to 14.4 V DC
Approx. 0.8 kΩ
Min. 1.2 V
24 V DC
21.6 to 26.4 V DC
Approx. 1.8 kΩ
Min. 2.4 V
Control voltage
Input impedance
Drop-out voltage
1
Input side
*
At ambient temperature of 30°C or
less
Max. load current
2 A*2
Load voltage
Frequency
75 to 250 Vrms
45 to 65 Hz
600 V
Repetitive peak OFF voltage
Non-repetitive surge current
Load side
30 A*3
In one cycle at 60 Hz
at 60 Hz
Max. “OFF-state” leakage
current
5 mA (200 Vrms applied)
Max. “ON-state” voltage drop
Min. load current
1.6 V
50 mA*4
at max. carrying current
OFF state dV/dt
50 V/μs
At ambient temperature of 80°C
• 3 A type
Part No.
AQ3A2-C1-T5VDC
AQ3A2-C2-T5VDC
AQ3A2-C1-T12VDC
AQ3A2-C2-T12VDC
AQ3A2-C1-T24VDC
AQ3A2-C2-T24VDC
Remarks
Item
Rated voltage
5 V DC
4 to 6 V DC
Approx. 0.3 kΩ
Min. 0.5 V
12 V DC
9.6 to 14.4 V DC
Approx. 0.8 kΩ
Min. 1.2 V
24 V DC
21.6 to 26.4 V DC
Approx. 1.8 kΩ
Min. 2.4 V
Control voltage
Input impedance
Drop-out voltage
1
Input side
*
At ambient temperature of 30°C or
less
Max. load current
3 A*2
Load voltage
75 to 250 Vrms
45 to 65 Hz
600 V
Frequency
Repetitive peak OFF voltage
Non-repetitive surge current
Load side
80 A*3
In one cycle at 60 Hz
at 60 Hz
Max. “OFF-state” leakage
current
5 mA (200 Vrms applied)
Max. “ON-state” voltage drop
Min. load current
1.6 V
50 mA*4
at max. carrying current
OFF state dV/dt
50 V/μs
At ambient temperature of 80°C
Notes: *1. Refer to REFERENCE DATA “3. Characteristics of input current vs. input voltage”.
*2. Refer to REFERENCE DATA “1. Characteristics of load current vs. ambient temperature”.
*3. Refer to REFERENCE DATA “2. characteristics of non-repetitive surge current vs. carrying time”.
*4. When the load current is less than the rated minimum load current, please refer to “Cautions for Use of Solid State Relays”.
2. Characteristics (Ambient temperature: 20°C 68°F; Input voltage ripple: 1% or less)
Type
Zero-cross type
Random type
Remarks
Item
Operate time, max.
Release time, max.
Insulation resistance, min.
Breakdown voltage
1/2 cycle of voltage sine wave +1 ms
1 ms
1/2 cycle of voltage sine wave +1 ms
109 Ω between input and output
3,000 Vrms between input and output
10 to 55 Hz at double amplitude of 3 mm
10 to 55 Hz at double amplitude of 3 mm
Min. 980 m/s2 {100 G}
at 500 V DC
For 1 minute
Destructive
1 hour for X, Y, Z axis
Vibration resistance
Shock resistance
Functional
Destructive
Functional
10 min. for X, Y, Z axis
5 times each for X, Y, Z axis
4 times each for X, Y, Z axis
Non-condensing at low temperatures
Non-condensing at low temperatures
Min. 980 m/s2 {100 G}
Ambient temperature
Storage temperature
Operational method
–30 to +80°C –22 to +176°F
–30 to +100°C –22 to +212°F
Zero-cross (Turn ON and Turn OFF)
Random turn ON, zero-cross turn OFF
ASCTB213E 201809-T