Click on Series name for product info on aimtec.com
Series AME1-AZ
1Watt | AC-DC Converter
FEATURES:
I/O Isolation 3000VAC
RoHS compliant
Energy Star compliant
Operating Temp: -40°C to +80°C
Input: 90-305VAC, 47-440Hz, or 130-430 VDC
Optional 90-528VAC, 47-440Hz, or 130-745 VDC
Over load, Short Circuit Protection
Ultra small package
Models
Single output
Maximum
capacitive
Efficiency
(%)
Input
Voltage
(VAC/Hz)
Input
Voltage
(VDC)
Temperature
range
Output
Voltage
(V)
Output
Current max
(mA)
Model
Load
(µF)
115
230
277
480
(ºC)
VAC
VAC
VAC
VAC
AME1-3.3SAZ
AME1-5SAZ
AME1-12SAZ
AME1-15SAZ
AME1-24SAZ
90-305/47-440
90-305/47-440
90-305/47-440
90-305/47-440
90-305/47-440
130-430
130-430
130-430
130-430
130-430
-40 to +80
-40 to +80
-40 to +80
-40 to +80
-40 to +80
3.3
5
12
15
24
300
200
83
67
42
2200
1100
680
560
470
62
58
73
77
79
59
57
68
68
79
58
56
65
70
77
AME1-3.3SBAZ
AME1-5SBAZ
AME1-12SBAZ
AME1-15SBAZ
AME1-24SBAZ
90-528/47-440
90-528/47-440
90-528/47-440
90-528/47-440
90-528/47-440
130-745
130-745
130-745
130-745
130-745
-40 to +80
-40 to +80
-40 to +80
-40 to +80
-40 to +80
3.3
5
12
15
24
300
200
83
67
42
2200
1100
680
560
470
51
57
62
61
58
51
57
62
59
58
50
56
60
58
56
44
50
51
50
48
Input Specifications
Parameters
Conditions
115 VAC
230 VAC
277 VAC
480VAC
Typical
Maximum
Units
mA
mA
mA
mA
A
A
A
A
25
20
15
5
10
15
20
30
Current (full load)
115 VAC
230 VAC
277 VAC
480 VAC
Inrush current <2ms (cold start)
Leakage current
External fuse
0.15
mA
A
1
Recommended slow blow type
Input Dissipation (No Load)
W
≦0.3
Output Specifications
Parameters
Voltage accuracy
Line regulation
Load regulation (single output)
Transient Recovery Time
Transient Response Deviation
Minimum load
Conditions
Full load (typical)*
LL-HL, Full Load
Typical
±5
±1.5
±5
Maximum
Units
%
%
%
µs
0-100% load (typical)*
200
±2
0
25% load step
% of Vout
%
3.3/5 VDC With 560µF E/C
12/15 VDC With 220µF E/C
24 VDC With 220µF E/C
200
400
500
mV p-p
mV p-p
mV p-p
Ripple & Noise
*Ripple &Noise measured at 20MHz bandwidth with 0.1µF and 115/230/277/480 VAC (Typical input) with Full Load.
Isolation Specifications
Parameters
Conditions
Typical
Rated
3000
Units
VAC
MΩ
Tested I/O voltage
60 sec
Isolation Resistance
>1000
www.aimtec.com
F 052e R8.H
Tel: +1 514 620 2722
1 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only