AC-DC Power Supplies
AKM36 Series
36 Watt
• Energy Efficiency Level VI
xxx Series
• European CoC Tier 2
• Medical and ITE Approvals
• Class II Construction
• Optional White Versions
• Output Voltages from 9 V to 36 V
• 3 Years Warranty
Dimensions:
The AKM36 series of desktop adaptors comply with the latest energy efficiency level VI standards
with high active mode efficiency and extremely low no load power consumption. Available with a
standard jack plug connector these adaptors suit a wide variety of cost sensitive industrial and
medical applications while maintaining industry leading performance.
AKM:
4.25 x 1.97 x 1.33” (108.0 x 50.0 x 33.8 mm)
Models & Ratings
Output Power
Output Voltage
Output Current
Total Regulation(1)
Efficiency(2)
Model Number(3)
9.0 V
12.0 V
15.0 V
18.0 V
24.0 V
30.0 V
36.0 V
4.0 A
3.0 A
2.4 A
2.0 A
1.5 A
1.2 A
1.0 A
5%
5%
5%
5%
5%
5%
5%
88.9%
89.3%
88.4%
89.5%
89.4%
89.9%
89.2%
AKM36US09C2
AKM36US12C2
AKM36US15C2
AKM36US18C2
AKM36US24C2
AKM36US30C2
AKM36US36C2
36 W
Notes
1. Total regulation includes initial set accuracy, line and load regulation.
2. Typical average value measured at 25%, 50%, 75% and 100% at 230 VAC.
3. For white case version add suffix ‘-W’ e.g. AKM36US12C2-W. MOQ applies,
contact sales for details.
Input
Characteristic
Minimum
Typical
Maximum
Units
VAC
Hz
A
A
Notes & Conditions
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
90
47
264
63
1.0
70
90 VAC
230 VAC, cold start at 25 °C
EN61000-3-2, class A
No Load Input Power
Input Protection
75
mW
Internal fuse in line
Output
Characteristic
Output Voltage
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
Minimum
Typical
Maximum
Units
V
A
Notes & Conditions
9
0
36
See Models and Ratings table
No minimum load required
4
s
30
ms
ms
%
10
Full load and 100 VAC
See Models and Ratings table
Recovery within <1% within 500 µs for a 60% step load
change at 0.15 A/µs
Total Regulation
5
4
Transient Response
Ripple & Noise
% deviation
mV pk-pk
Measured with 20 MHz bandwidth and 10 µF electrolytic in
parallel with 0.1 µF ceramic capacitor
200
Short Circuit Protection
Temperature Coefficient
Continuous, trip and restart (hiccup mode) with auto recovery
0.05
%/˚C
www.xppower.com