3) High sensitivity single side stable type
Nominal operating
current
[ 10%] (at 20°C 68°F)
Nominal coil
voltage
Set voltage
(at 20°C 68°F)
Reset voltage
(at 20°C 68°F)
Coil resistance
[ 10%] (at 20°C 68°F)
Nominal operating
power
Max. applied voltage
(at 20°C 68°F)
1.5V DC
3V DC
66.7mA
33.3mA
22.2mA
16.7mA
11.1mA
8.3mA
22.5Ω
90Ω
202.5Ω
360Ω
810Ω
1,440Ω
4.5V DC
6V DC
150%V of
nominal voltage
100mW
120mW
80%V or less of
nominal voltage*
(Initial)
10%V or more of
nominal voltage*
(Initial)
9V DC
12V DC
120%V of
nominal voltage
24V DC
5.0mA
4,800Ω
*Pulse drive (JIS C 5442-1996)
2. Specifications
Characteristics
Item
Specifications
Arrangement
2 Form C
Contact
Rating
Initial contact resistance, max.
Contact material
Max. 100 mΩ (By voltage drop 6 V DC 1A)
Stationary contact: AgPd+Au clad Movable contact: AgPd
2 A 30 V DC, 1 A 30 V DC, 0.3 A 125 V AC (resistive load)
60 W (DC), 30 W (DC), 37.5 V A (AC) (resistive load)
110 V DC, 125 V AC
Nominal switching capacity
Max. switching power
Max. switching voltage
Max. switching current
Min. switching capacity (Reference value)*1
2 A
10µA 10 mV DC
Single side stable
140mW (1.5 to 12 V DC), 230mW (24 V DC)
Nominal operating
power
High sensitivity single side
stable type
100mW (1.5 to 12 V DC), 120mW (24 V DC)
1 coil latching
Min. 1,000MΩ (at 500V DC)
Measurement at same location as “Initial breakdown voltage” section.
Insulation resistance (Initial)
Between open contacts
750 Vrms for 1min. (Detection current: 10mA)
1,500 Vrms for 1min. (Detection current: 10mA)
1,000 Vrms for 1min. (Detection current: 10mA)
1,500 V (10×160µs) (FCC Part 68)
2,500 V (2×10µs) (Telcordia)
Breakdown voltage
(Initial)
Between contact and coil
Between contact sets
Electrical
characteristics
Between open contacts
Between contacts and coil
Surge breakdown
voltage (Initial)
Max. 50°C
Temperature rise (at 20°C 68°F)
(By resistive method, nominal coil voltage applied to the coil; contact carrying current: 1A.)
Max. 4 ms [Max. 4 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.)
Operate time [Set time] (at 20°C 68°F)
Release time [Reset time] (at 20°C 68°F)
Max. 4 ms [Max. 4 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.)
(without diode)
Functional
Shock resistance
Min. 750 m/s2 (Half-wave pulse of sine wave: 6 ms; detection time: 10µs.)
Min. 1,000 m/s2 (Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 3.3 mm (Detection time: 10µs.)
10 to 55 Hz at double amplitude of 5 mm
Destructive
Mechanical
characteristics
Functional
Vibration resistance
Destructive
Mechanical
Min. 5 × 107 (at 180 cpm)
Min. 5 × 104 (2 A 30 V DC resistive), Min. 105 (1 A 30 V DC resistive),
Expected life
Electrical
Min. 105 (0.3 A 125 V AC resistive) (at 20 cpm)
Ambient temperature:
(Single side stable, 1 coil latching type) –40°C to +85°C –40°F to +185°F
(High sensitivity single side stable type) –40°C to +70°C –40°F to +158°F
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Conditions for operation, transport and storage*2
Max. operating speed (at rated load)
Conditions
Unit weight
20 cpm
Approx. 1 g .035 oz
Notes: *1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2 Refer to 6. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 24).
REFERENCE DATA
1. Max. switching capacity
2. Life curve
3. Mechanical life
* Max. switching capacity is 2A 30V DC.
Tested sample: AGQ200A4H, 6 pcs.
Operating speed: 180 cpm
100
4
DC resistive load
AC resistive load
50
40
1.0
0.3
Pick-up voltage
3
Max.
Min.
30
DC 30V resistive load
20
2
AC 125V
resistive load
Drop-out voltage
1
10
0
Max.
Min.
0
0
10
30
50
0.2
0.4
0.6
0.8
1.0
1.2
30
100
Contact voltage, V
No. of operations, ×104
Switching current, A
ASCTB7E 201209-T