Table 1. Regulatory Compliance
Feature
Test Method
Performance
ElectrostaticꢀDischargeꢀ(ESD)ꢀ
toꢀtheꢀElectricalꢀContactsꢀ
MIL-STD-883Cꢀꢀ
Methodꢀ3015.4
Classꢀ1ꢀꢀ(>ꢀ2000ꢀVolts)ꢀ
ElectrostaticꢀDischargeꢀ(ESD)ꢀ
toꢀtheꢀDuplexꢀLCꢀReceptacleꢀ
ꢀ
IECꢀ61000-4-2ꢀ
ꢀ
ꢀ
Typically,ꢀnoꢀdamageꢀoccursꢀwithꢀ25ꢀkVꢀwhenꢀ
theꢀduplexꢀLCꢀconnectorꢀreceptacleꢀisꢀ
contactedꢀbyꢀaꢀHumanꢀBodyꢀModelꢀprobe.ꢀ
LifeꢀTrafficꢀESDꢀImmunityꢀ
ꢀ
IECꢀ61000-4-2ꢀ
ꢀ
10ꢀcontactsꢀofꢀ8ꢀkVꢀonꢀtheꢀelectricalꢀfaceplateꢀ
withꢀdeviceꢀinsertedꢀintoꢀaꢀpanel.ꢀ
LifeꢀTrafficꢀESDꢀImmunityꢀ
ꢀ
IECꢀ61000-4-2ꢀ
ꢀ
Airꢀdischargeꢀofꢀ15ꢀkVꢀ(min.)ꢀcontactꢀtoꢀ
connectorꢀwithoutꢀdamage.ꢀ
Electromagneticꢀ
Interferenceꢀ(EMI)ꢀ
ꢀ
ꢀ
FCCꢀClassꢀBꢀ
CENELECꢀEN55022ꢀClassꢀBꢀ
(CISPRꢀ22A)ꢀ
Systemꢀmarginsꢀareꢀdependentꢀonꢀcustomerꢀ
boardꢀandꢀchassisꢀdesign.ꢀ
VCCIꢀClassꢀ1ꢀ
RFꢀImmunityꢀ
ꢀ
IECꢀ61000-4-3ꢀ
ꢀ
Typicallyꢀshowsꢀnoꢀmeasurableꢀeffectꢀfromꢀaꢀ10ꢀꢀ
V/mꢀfieldꢀsweptꢀfromꢀ80MHzꢀtoꢀ1ꢀGHz
LaserꢀEyeꢀSafetyꢀandꢀ
USꢀFDAꢀCDRHꢀAELꢀClassꢀ1ꢀ
US21ꢀCFR,ꢀSubchapterꢀJꢀperꢀ
Paragraphsꢀ1002.10ꢀandꢀ1002.12ꢀ
CDRHꢀAccessionꢀNo.ꢀ9720151-072ꢀ
TUVꢀFileꢀRꢀ72071411ꢀpageꢀ2ꢀ
EquipmentꢀTypeꢀTestingꢀ
ꢀ
BAUART
GEPRUFT
ꢀ
¨
ꢀ
ꢀ
ꢀ
ꢀ
(IEC)ꢀEN60825-1:ꢀ1994ꢀ+ꢀA11ꢀ+ꢀA2ꢀ
(IEC)ꢀEN60825-2:ꢀ1994ꢀ+ꢀA1ꢀ
(IEC)ꢀEN60950:ꢀ1992ꢀ+ꢀA1ꢀ+ꢀA2ꢀ+ꢀA3ꢀꢀ
+ꢀA4ꢀ+ꢀA11
¨
TUV
TYPE
APPROVED
Rheinland
Product Safety
ComponentꢀRecognitionꢀ
UnderwritersꢀLaboratoriesꢀandꢀCanadianꢀ ULꢀfileꢀE173874ꢀ
StandardsꢀAssociationꢀJointꢀComponentꢀ
RecognitionꢀforꢀInformationꢀTechnologyꢀ
EquipmentꢀincludingꢀElectricalꢀBusinessꢀ
Equipment
ꢀ
ꢀ
ꢀ
ꢀ
RoHSꢀComplianceꢀ
ꢀ
RoHSꢀDirectiveꢀ2002/95/ECꢀandꢀꢀ
it’sꢀamendmentꢀdirectivesꢀ6/6ꢀ
SGSꢀTestꢀReportꢀNo.ꢀLPC/13392ꢀ(AD-1)/07ꢀ
CTSꢀRef.ꢀCTS/07/3283/Avago
ꢀ
6