EV (AEV)  
NOTES  
1. Usage, transport and storage conditions  
1) Temperature: –40 to +80°C –40 to +176°F  
2) Humidity: 5 to 85% RH (Avoid freezing and condensation.)  
The humidity range varies with the temperature. Use within the  
range indicated in the graph below.  
4. Electrical life  
This relay is a high-voltage direct-current switch. In its final  
breakdown mode, it may lose the ability to provide the proper  
cut-off. Therefore, do not exceed the indicated switching  
capacity and life. (Please treat the relay as a product with limited  
life and replace it when necessary.)  
In the event that the relay loses cut-off ability, there is a  
possibility that burning may spread to surrounding parts, so  
configure the layout so that the power is turned off within one  
second.  
3) Atmospheric pressure: 86 to 106 kPa  
Temperature and humidity range for usage, transport, and  
storage  
Humidity, %RH  
85  
Tolerance range  
5. Permeation life of internal gas  
This relay uses a hermetically encased contact (capsule  
contact) with gas inside. The gas has a permeation life that is  
affected by the temperature inside the capsule contact (ambient  
temperature + temperature rise due to flow of electrical current).  
For this reason, make sure the ambient operating temperature is  
between –40 and 80°C –40 and +176°F (200A and 300A types:  
Max. 85°C 185°F), and the ambient storage temperature is  
between –40 and 85°C –40 and +185°F.  
(Avoid freezing (Avoid  
when used at  
temperatures  
lower than  
0°C 32°F)  
condensation  
when used at  
temperatures  
higher than  
0°C 32°F)  
5
–40  
–40  
0
+32  
80  
+176  
Temperature, °C °F  
4) Condensation  
Condensation forms when there is a sudden change in  
temperature under high temperature and high humidity  
conditions. Condensation will cause deterioration of the relay  
insulation.  
6.The coils (300 A type) and contacts (all type) of the relay  
are polarized, so follow the connection schematic when  
connecting the coils and contacts.  
5) Low temperature, low humidity environments  
The plastic becomes brittle if the relay is exposed to a low  
temperature, low humidity environment for long periods of time.  
Type 300 A contains a reverse surge voltage absorption circuit;  
therefore a surge protector is not needed.  
7. For the 300 A type, drive the coil with a quick startup.  
2. When installing the relay, always use washers to prevent  
the screws from loosening.  
(Built-in one-shot pulse generator circuit)  
• Regarding the torque value for contact terminal, it is intended  
that secure an electrical connection stability by getting enough  
contact pressure (Axial force) of fixing part.  
Therefore, please do not use the screw (a bolt and a nut)  
preventing looseness needing running torque (Prevailing torque  
type and Self lock type) because enough tightening force in axial  
direction may not be secured.  
In addition, there is high possibility that a case of a relay may be  
broken if users use the nut for EV80A and EV120A.  
Because excessive torque is applied to a case of a relay before  
generation of contact pressure. (Axial force).  
• Regarding the torque value for the main body of a relay, please  
use suitable screw on own verification.  
8. After the ON signal enters the 300A type, automatic coil  
current switching occurs after approximately 0.1 seconds.  
Do not repeatedly turn it OFF within that 0.1 seconds  
interval, as doing so may damage the relay.  
9. Be careful that foreign matter and oils and fats kind don’t  
stick to the main terminal parts because it is likely to cause  
terminal parts to give off unusual heat.  
Also, please use the following materials for connected  
harnesses and bus bars.  
10A type: Min. 2 mm2 nominal cross-sectional area  
20A type: Min. 3 mm2 nominal cross-sectional area  
80A type: Min. 15 mm2 nominal cross-sectional area  
120A type: Min. 38 mm2 nominal cross-sectional area  
200A type: Min. 60 mm2 nominal cross-sectional area  
300A type: Min. 100 mm2 nominal cross-sectional area  
3. Condition of tightening screw  
Tighten each screw within the rated range given below.  
Exceeding the maximum torque may result in breakage.  
Mounting is possible in either direction.  
<Relay attaching portion>  
• M4 screw (for 10A type): 1.8 to 2.7 N·m  
• M5 screw (for 20A, 80A, 120A, 200A and 300A types): 3 to 4  
N·m  
10. As a guide, the insertion strength of the plug-in terminal  
into the relay tab terminal should be 40 to 70N (10A type), 40  
to 80N (20A type). Please select a plug-in terminal (flat  
connection terminal) which comply with JIS C2809-1999.  
10A type: for plate thickness 0.5mm and #187 tab terminal  
20A type: for plate thickness 0.8mm and #250 tab terminal  
<Main terminal attaching portion>  
• M5 (for 80A type): 3 to 4 N·m  
• M6 (for 120A and 200A types): 6 to 8 N·m  
• M8 (for 300A type): 10 to 12 N·m  
11. Avoid excessive load applied to the terminal in case of  
installing such as a bus bar etc., Because it might adversely  
affect the opening and closing performance.  
12. Use the specified connector for the connector terminal  
connection (80A, 120A and 300A)  
Yazaki Corporation 7283 – 1020 or equivalent  
ASCTB233E 201209-T  
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/  

与AEV14012W相关器件

型号 品牌 描述 获取价格 数据表
AEV14024 PANASONIC Capsule contact Mechanism and High-capacity Cut-off Compact Relay

获取价格

AEV140242 PANASONIC Power/Signal Relay

获取价格

AEV15012 PANASONIC Power/Signal Relay, SPST, Momentary, 2.8A (Coil), 12VDC (Coil), 5000mW (Coil), 150A (Conta

获取价格

AEV15024 PANASONIC Power/Signal Relay, SPST, Momentary, 2.2A (Coil), 24VDC (Coil), 5000mW (Coil), 150A (Conta

获取价格

AEV16012 PANASONIC Power/Signal Relay, SPST, Momentary, 0.415A (Coil), 12VDC (Coil), 5000mW (Coil), 60A (Cont

获取价格

AEV16024 PANASONIC Power/Signal Relay, SPST, Momentary, 0.208A (Coil), 24VDC (Coil), 5000mW (Coil), 60A (Cont

获取价格