xppower.com
60 Watts
AEM60 Series
•
•
•
•
•
•
•
CEC 2008 & EISA 2007 Compliant 12 V
Worldwide Medical Approvals
4000 VAC Isolation
Class II Construction
Single Outputs from 5 V to 48 V
High Efficiency
3 Year Warranty
Specification
Input
General
Input Voltage
• 80-264 VAC, derate output power 5%
Efficiency
• 85%, see note 5
<90 VAC and 10% <85 VAC
• 47-63 Hz
• 1.5 A rms max
• 80 A max at 240 VAC
• Fitted with a T2 A/250 VAC fuse in live line
Isolation
• 4000 VAC Input to Output
• 100 kHz typical
• 4.2 W/Inch
• 300 kHrs to MIL-HDBK-217F
at 25 ˚C, GB
Input Frequency
Input Current
Switching Frequency
Power Density
MTBF
3
Inrush Current
Input Protection
No Load Input Power • <0.5 W for ≥12 V output
Environmental
Operating Temperature • 0 ꢀC to +60 ꢀC, derate linearly from 100%
Output
load at +40 ꢀC to 50% load at +60 ꢀC
Cooling
• Convection-cooled
• 15-95% non-condensing
Output Voltage
Initial Set Accuracy
Minimum Load
• See table
• See table
• No mimimum load required
• 3 s max
• 3 ms
Operating Humidity
Storage Temperature • -20 ꢀC to +85 ꢀC
Operating Altitude
Vibration
• 3000 m
Start Up Delay
• 5-500 Hz at 3 g for 10 mins on each axis
• 30 g with 18 ms half sine wave,
3 times on each axis
Start Up Rise Time
Hold Up Time
Shock
• 8 ms minimum at 115 VAC
Line Regulation
Load Regulation
Transient Response
•
1%
• See table
• 5% max deviation recovering to within 1%
within 500 µs for 50% load change
EMC & Safety
Emissions
• EN55011 Level B conducted & radiated
• EN61000-3-2, class A
• EN61000-3-3
• EN61000-4-2 Level 3, Perf Criteria A
• EN61000-4-3 Level 2, Perf Criteria A
• EN61000-4-4, Level 3, Perf Criteria A
• EN61000-4-5 Level 3, Perf Criteria A
• EN61000-4-6 Level 3, Perf Criteria A
Ripple & Noise
• 1% max, 20 MHz bandwidth (see note 2)
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Overvoltage Protection • See table
Overload Protection • 120-150%, trip & restart (hiccup mode),
auto-recovery
Short Circuit Protection • Continuous
Temperature
Coefficient
•
0.05%/ꢀC
Surge
Conducted Immunity
Dips & Interruptions
• EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms Perf Criteria A, B, B
Safety Approvals
• UL60601-1, EN60601-1, IEC60601-1,
CE Mark