亚德诺 - ADI 转换器驱动程序和接口接口集成电路光电二极管
页数 文件大小 规格书
24页 536K
描述
Quad-Channel Isolators with Integrated DC-to-DC Converter

ADUM5402WCRWZ-1 技术参数

Source Url Status Check Date:2013-05-01 14:56:51.211是否无铅: 含铅
是否Rohs认证: 符合生命周期:Active
零件包装代码:SOIC包装说明:SOIC-16
针数:16Reach Compliance Code:compliant
ECCN代码:EAR99HTS代码:8543.70.99.60
风险等级:2.12Is Samacsys:N
接口集成电路类型:INTERFACE CIRCUITJESD-30 代码:R-PDSO-G16
JESD-609代码:e3长度:10.3 mm
湿度敏感等级:3功能数量:1
端子数量:16最高工作温度:105 °C
最低工作温度:-40 °C封装主体材料:PLASTIC/EPOXY
封装代码:SOP封装等效代码:SOP16,.4
封装形状:RECTANGULAR封装形式:SMALL OUTLINE
峰值回流温度(摄氏度):260座面最大高度:2.65 mm
最大供电电压:5.5 V最小供电电压:3 V
标称供电电压:3.3 V表面贴装:YES
温度等级:INDUSTRIAL端子面层:Matte Tin (Sn)
端子形式:GULL WING端子节距:1.27 mm
端子位置:DUAL处于峰值回流温度下的最长时间:30
宽度:7.5 mmBase Number Matches:1

ADUM5402WCRWZ-1 数据手册

 浏览型号ADUM5402WCRWZ-1的Datasheet PDF文件第7页浏览型号ADUM5402WCRWZ-1的Datasheet PDF文件第8页浏览型号ADUM5402WCRWZ-1的Datasheet PDF文件第9页浏览型号ADUM5402WCRWZ-1的Datasheet PDF文件第11页浏览型号ADUM5402WCRWZ-1的Datasheet PDF文件第12页浏览型号ADUM5402WCRWZ-1的Datasheet PDF文件第13页 
ADuM5401W/ADuM5402W/ADuM5403W  
Data Sheet  
DIN EN 69747-5-2 (VDE 0884 TEIL 2) INSULATION CHARACTERISTICS  
These isolators are suitable for reinforced electrical isolation only within the safety limit data. Maintenance of the safety data is ensured by  
the protective circuits. The asterisk (*) marking on packages denotes DIN EN 69747-5-2 (VDE 0884 Teil 2):2003-1 approval.  
Table 17. VDE Characteristics  
Description  
Conditions  
Symbol Characteristic Unit  
Installation Classification per DIN VDE 0110  
For Rated Mains Voltage ≤ 150 V rms  
For Rated Mains Voltage ≤ 300 V rms  
For Rated Mains Voltage ≤ 400 V rms  
Climatic Classification  
Pollution Degree per DIN VDE 0110, Table 1  
Maximum Working Insulation Voltage  
Input-to-Output Test Voltage, Method b1  
I to IV  
I to III  
I to II  
40/105/21  
2
VIORM  
VPR  
565  
1059  
V peak  
V peak  
VIORM × 1.875 = VPR, 100% production test, tm = 1 sec,  
partial discharge < 5 pC  
Input-to-Output Test Voltage, Method a  
After Environmental Tests Subgroup 1  
After Input and/or Safety Test Subgroup 2  
and Subgroup 3  
VPR  
VIORM × 1.6 = VPR, tm = 60 sec, partial discharge < 5 pC  
VIORM × 1.2 = VPR, tm = 60 sec, partial discharge < 5 pC  
904  
678  
V peak  
V peak  
Highest Allowable Overvoltage  
Safety Limiting Values  
Transient overvoltage, tTR = 10 sec  
Maximum value allowed in the event of a failure  
(see Figure 5)  
VTR  
4000  
V peak  
Case Temperature  
Side 1 IDD1 Current  
Insulation Resistance at TS  
TS  
IS1  
RS  
150  
555  
>109  
°C  
mA  
Ω
VIO = 500 V  
600  
500  
400  
300  
200  
100  
0
0
50  
100  
150  
200  
AMBIENT TEMPERATURE (°C)  
Figure 5. Thermal Derating Curve, Dependence of Safety Limiting Values on Case Temperature, per DIN EN 60747-5-2  
RECOMMENDED OPERATING CONDITIONS  
Table 18.  
Parameter  
Operating Temperature1  
Supply Voltages2  
Symbol  
TA  
VDD1  
Min  
−40  
3.0  
Max  
+105  
5.5  
Unit  
°C  
V
1 Operation at 105°C requires reduction of the maximum load current, as specified in Table 19.  
2 Each voltage is relative to its respective ground.  
Rev. D | Page 10 of 24  
 
 
 
 
 

与ADUM5402WCRWZ-1相关器件

型号 品牌 描述 获取价格 数据表
ADUM5402WCRWZRL ADI SPECIALTY ANALOG CIRCUIT, PDSO16, ROHS COMPLIANT, MS-013AA, SOIC-16

获取价格

ADUM5402WCRWZ-RL ADI 暂无描述

获取价格

ADUM5403 ADI Quad-Channel Isolators with Integrated DC-to-DC Converter

获取价格

ADUM5403ARWZ ADI Quad-Channel, 2.5 kV Isolators with Integrated DC-to-DC Converter

获取价格

ADUM5403ARWZ1 ADI Quad-Channel Isolators with Integrated DC-to-DC Converter

获取价格

ADUM5403ARWZ2 ADI Quad-Channel Isolators with Integrated DC-to-DC Converter

获取价格