ADuM2210/ADuM2211
Data Sheet
PACKAGE CHARACTERISTICS
Table 4.
Parameter
Symbol
RI-O
CI-O
CI
θJCI
Min
Typ
1012
2.2
4.0
33
Max
Unit
Ω
pF
pF
°C/W
°C/W
Test Conditions
Resistance (Input-to-Output)1
Capacitance (Input-to-Output)1
Input Capacitance2
f = 1 MHz
IC Junction-to-Case Thermal Resistance, Side 1
IC Junction-to-Case Thermal Resistance, Side 2
Thermocouple located at
center of package underside
θJCO
28
1 Device considered a 2-terminal device: Pin 1 through Pin 8 are shorted together and Pin 9 through Pin 16 are shorted together.
2 Input capacitance is from any input data pin to ground.
REGULATORY INFORMATION
The ADuM221x are approved by the organizations listed in Table 5. Refer to Table 10 and the Insulation Lifetime section for details
regarding recommended maximum working voltages for specific cross-isolation waveforms and insulation levels.
Table 5.
UL
CSA
VDE
Recognized under 1577 Component
Recognition Program1
Approved under CSA Component
Acceptance Notice #5A
Certified according to DIN V VDE V 0884-10 (VDE V
0884-10): 2006-122
Single Protection
5000 V rms Isolation Voltage
Basic insulation per CSA 60950-1-07 and IEC Reinforced insulation, 846 V peak
60950-1, 600 V rms (848 V peak) maximum
working voltage
RW-16 package:
Reinforced insulation per CSA 60950-1-07
and IEC 60950-1, 380 V rms (537 V peak)
maximum working voltage; reinforced
insulation per IEC 60601-1 125 V rms
(176 V peak) maximum working voltage
RI-16 package:
Reinforced insulation per CSA 60950-1-07
and IEC 60950-1, 400 V rms (565 V peak)
maximum working voltage; reinforced
insulation per IEC 60601-1 250 V rms
(353 V peak) maximum working voltage
File E214100
File 205078
File 2471900-4880-0001
1 In accordance with UL1577, each ADuM221x is proof tested by applying an insulation test voltage ≥ 6000 V rms for 1 second (current leakage detection limit = 10 μA).
2 In accordance with DIN V VDE V 0884-10, each ADuM221x is proof tested by applying an insulation test voltage ≥1590 V peak for 1 sec (partial discharge detection
limit = 5 pC). The * marking branded on the component designates DIN V VDE V 0884-10 approval.
INSULATION AND SAFETY-RELATED SPECIFICATIONS
Table 6.
Parameter
Symbol Value
Unit
Conditions
Rated Dielectric Insulation Voltage
Minimum External Air Gap
5000
8.0 min
V rms 1-minute duration
L(I01)
mm
Distance measured from input terminals to output
terminals, shortest distance through air along the PCB
mounting plane, as an aid to PC board layout
Minimum External Tracking (Creepage) RW-16 Package L(I02)
Minimum External Tracking (Creepage) RI-16 Package L(I02)
Minimum Internal Gap (Internal Clearance)
7.7 min
8.3 min
mm
mm
Measured from input terminals to output terminals,
shortest distance path along body
Measured from input terminals to output terminals,
shortest distance path along body
Insulation distance through insulation
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
0.017 min mm
>175
IIIa
Tracking Resistance (Comparative Tracking Index)
Isolation Group
CTI
V