ADM1032AR

更新时间: 2024-02-13 05:10:13
品牌 Logo 应用领域
亚德诺 - ADI 监控
页数 文件大小 规格书
12页 166K
描述
+-1C Remote and Local System Temperature Monitor

ADM1032AR 技术参数

是否无铅: 不含铅是否Rohs认证: 符合
生命周期:Transferred零件包装代码:SOIC
包装说明:SOP,针数:8
Reach Compliance Code:unknownECCN代码:EAR99
HTS代码:8542.39.00.01风险等级:5
Is Samacsys:N其他特性:PROGRAMMABLE OVER/UNDER TEMPERATURE LIMIT
模拟集成电路 - 其他类型:ANALOG CIRCUITJESD-30 代码:R-PDSO-G8
JESD-609代码:e3长度:4.9 mm
湿度敏感等级:1功能数量:1
端子数量:8最高工作温度:120 °C
最低工作温度:封装主体材料:PLASTIC/EPOXY
封装代码:SOP封装形状:RECTANGULAR
封装形式:SMALL OUTLINE峰值回流温度(摄氏度):260
认证状态:Not Qualified座面最大高度:1.75 mm
最大供电电压 (Vsup):5.5 V最小供电电压 (Vsup):3 V
标称供电电压 (Vsup):3.3 V表面贴装:YES
温度等级:OTHER端子面层:Matte Tin (Sn)
端子形式:GULL WING端子节距:1.27 mm
端子位置:DUAL处于峰值回流温度下的最长时间:40
宽度:3.9 mmBase Number Matches:1

ADM1032AR 数据手册

 浏览型号ADM1032AR的Datasheet PDF文件第4页浏览型号ADM1032AR的Datasheet PDF文件第5页浏览型号ADM1032AR的Datasheet PDF文件第6页浏览型号ADM1032AR的Datasheet PDF文件第8页浏览型号ADM1032AR的Datasheet PDF文件第9页浏览型号ADM1032AR的Datasheet PDF文件第10页 
ADM1032  
Table V. Configuration Register Bit Assignments  
Power-On  
Consecutive ALERT Register  
This value written to this register determines how many out-of-  
limit measurements must occur before an ALERT is generated.  
The default value is that one out-of-limit measurement gener-  
ates an ALERT. The max value that can be chosen is 4. The  
purpose of this register is to allow the user to perform some filter-  
ing of the output. This is particularly useful at the faster two  
conversion rates where no averaging takes place.  
Bit  
Name  
Function  
Default  
7
MASK1  
0 = ALERT Enabled  
1 = ALERT Masked  
0 = Run  
1 = Standby  
Reserved  
0
6
RUN/STOP  
0
0
5–0  
Table VII.  
Conversion Rate Register  
Number of “Out-of-Limit”  
Measurements Required  
The lowest four bits of this register are used to program the  
conversion rate by dividing the internal oscillator clock by 1, 2,  
4, 8, 16, 32, 64, 128, 256, 512, or 1024 to give conversion  
times from 15.5 ms (code 0Ah) to 16 seconds (code 00h). This  
register can be written to and read back over the SMBus. The  
higher four bits of this register are unused and must be set to  
zero. Use of slower conversion times greatly reduces the device  
power consumption, as shown in Table VI.  
Register Value  
yxxx 000x  
yxxx 001x  
yxxx 011x  
yxxx 111x  
1
2
3
4
NOTES  
x = Don’t care bit.  
y = SMBus timeout bit. Default = 0. See SMBus section for more  
information.  
Table VI. Conversion Rate Register Codes  
Average Supply Current  
SERIAL BUS INTERFACE  
Data  
Conversion/sec  
mA Typ at VDD = 5.5 V  
Control of the ADM1032 is carried out via the serial bus. The  
ADM1032 is connected to this bus as a slave device, under the  
control of a master device.  
00h  
01h  
02h  
03h  
04h  
05h  
06h  
07h  
08h  
09h  
0Ah  
0B to FFh  
0.0625  
0.125  
0.25  
0.5  
1
2
4
8
0.17  
0.20  
0.21  
0.24  
0.29  
0.40  
0.61  
1.1  
There is a programmable SMBus timeout. When this is enabled  
the SMBus will timeout after typically 25 ms of no activity. How-  
ever, this feature is not enabled by default. To enable it, set Bit 7  
of the Consecutive Alert Register (Addr = 22h).  
The ADM1032 supports Packet Error Checking (PEC) and its  
use is optional. It is triggered by supplying the extra clock for the  
PEC byte. The PEC byte is calculated using CRC-8. The Frame  
Check Sequence (FCS) conforms to CRC-8 by the polynomial:  
16  
1.9  
32  
64  
0.73  
1.23  
C(x) = x8 + x2 + x1 + 1  
Reserved  
Consult SMBus 1.1 specification for more information  
(www.smbus.org).  
Limit Registers  
The ADM1032 has nine Limit Registers to store local and remote,  
high, low, and THERM temperature limits. These registers can  
be written to and read back over the SMBus.  
ADDRESSING THE DEVICE  
In general, every SMBus device has a 7-bit device address (except  
for some devices that have extended, 10-bit addresses). When  
the master device sends a device address over the bus, the slave  
device with that address will respond. The ADM1032 is avail-  
able with one device address, which is Hex 4C (1001 100).  
The high limit registers perform a > comparison while the low  
limit registers perform a < comparison. For example, if the high  
limit register is programmed with 80°C, then measuring 81oC  
will result in an alarm condition. If the Low Limit Register is  
programmed with 0°C, measuring 0°C or lower will result in  
Alarm condition. Exceeding either the Local or Remote THERM  
limit asserts THERM low. A default hysteresis value of 10°C is  
provided, which applies to both channels. This hysteresis may  
be reprogrammed to any value after power up (Reg 0x21h).  
The serial bus protocol operates as follows:  
1. The master initiates data transfer by establishing a START  
condition, defined as a high-to-low transition on the serial  
data line SDATA, while the serial clock line SCLK remains  
high. This indicates that an address/data stream will follow.  
All slave peripherals connected to the serial bus respond to  
the START condition, and shift in the next eight bits, con-  
sisting of a 7-bit address (MSB first) plus an R/W bit, which  
determines the direction of the data transfer, i.e., whether  
data will be written to or read from the slave device.  
One-Shot Register  
The One-Shot Register is used to initiate a single conversion  
and comparison cycle when the ADM1032 is in standby mode,  
after which the device returns to standby. This is not a data  
register as such, and it is the write operation that causes the  
one-shot conversion. The data written to this address is irrel-  
evant and is not stored. The conversion time on a single shot is  
96 ms when the conversion rate is 16 conversions per second or  
less. At 32 conversions per second the conversion time is 15.3 ms.  
This is because averaging is disabled at the faster conversion rates  
(32 and 64 conversions per second).  
The peripheral whose address corresponds to the transmitted  
address responds by pulling the data line low during the low  
period before the ninth clock pulse, known as the Acknowl-  
edge Bit. All other devices on the bus now remain idle while  
the selected device waits for data to be read from or written  
REV. 0  
–7–  

与ADM1032AR相关器件

型号 品牌 描述 获取价格 数据表
ADM1032AR-1 ADI IC SPECIALTY ANALOG CIRCUIT, PDSO8, MS-012AA, SOIC-8, Analog IC:Other

获取价格

ADM1032AR-1REEL ADI IC SPECIALTY ANALOG CIRCUIT, PDSO8, MS-012AA, SOIC-8, Analog IC:Other

获取价格

ADM1032AR-1REEL7 ROCHESTER SPECIALTY ANALOG CIRCUIT, PDSO8, MS-012AA, SOIC-8

获取价格

ADM1032ARM ADI +-1C Remote and Local System Temperature Monitor

获取价格

ADM1032ARM ONSEMI IC SPECIALTY ANALOG CIRCUIT, PDSO8, MO-187AA, MSOP-8, Analog IC:Other

获取价格

ADM1032ARM-1 ROCHESTER SPECIALTY ANALOG CIRCUIT, PDSO8, MO-187AA, MSOP-8

获取价格