AD53032
ABSOLUTE MAXIMUM RATINGS1
Environmental
Operating Temperature (Junction) . . . . . . . . . . . . . .+175°C
Storage Temperature . . . . . . . . . . . . . . . . –65°C to +150°C
Lead Temperature (Soldering, 10 sec)3 . . . . . . . . . .+260°C
Power Supply Voltage
+VS to GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +13 V
–VS to GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –8 V
+VS to –VS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +20 V
PWR GND to ECL GND or HQ GND . . . . . . . . . . ±0.4 V
Inputs
NOTES
1Stresses above those listed under Absolute Maximum Ratings may cause perma-
nent damage to the device. This is a stress rating only; functional operation of the
device at these or any other conditions above those indicated in the operational
sections of this specification is not implied. Absolute maximum limits apply
individually, not in combination. Exposure to absolute maximum rating condi-
tions for extended periods may affect device reliability.
DATA, DATA, IOD, IOD, RLD, RLD . . . . . . +5 V, –3 V
DATA to DATA, IOD to IOD, RLD to RLD . . . . . . . ±3 V
LEL, LEL, LEH, LEH . . . . . . . . . . . . . . . . . . . +5 V, –3 V
LEL to LEL, LEH to LEH . . . . . . . . . . . . . . . . . . . . . ±3 V
INHL, INHL . . . . . . . . . . . . . . . . . . . . . . . . . . . +5 V, –3 V
INHL to INHL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±3 V
VH, VL, VTERM, VCOM_I to GND . . . . . . . . +9 V, –4 V
VH to VL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±11 V
(VH–VTERM) and (VTERM – VL) . . . . . . . . . . . . . ±11 V
IOHC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±6 V
IOLC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±6 V
HCOMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +9 V, –4 V
LCOMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +9 V, –4 V
HCOMP, LCOMP to VOUT . . . . . . . . . . . . . . . . . . . ±11 V
Outputs
2Output short circuit protection is guaranteed as long as proper heatsinking is
employed to ensure compliance with the operating temperature limits.
3To ensure lead coplanarity (± 0.002 inches) and solderability, handling with bare
hands should be avoided and the device should be stored in environments at 24°C
± 5°C (75°F ± 10°F) with relative humidity not to exceed 65%.
Table IV. Package Thermal Characteristics
Air Flow, FM
JA, ؇C/W
0
200
400
33
25
22
VOUT Short Circuit Duration . . . . . . . . . . . . . . . .Indefinite2
VOUT Inhibit Mode . . . . . . . . . . . . . . . . . . . . . . . +9 V, –4 V
VHDCPL . . . . . . . .Do Not Connect Except for Cap to VCC
VLDCPL . . . . . . . . Do Not Connect Except for Cap to VEE
QH, QH, QL, QL Maximum IOUT
Continuous . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 mA
Surge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .100 mA
THERM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +13 V, 0 V
IOHRTN, IOLRTN . . . . . . . . . . . . . . . . . . +8.5 V, –3.5 V
VCOM_S Short Circuit Duration . . . . . . . . . . . . . . . 3 sec2
ORDERING GUIDE
Shipment Method
Package
Description
Quantity per
Shipping Container
Package
Option
Model
AD53032JSTP
52-Lead LQFP-EDQUAD
90
SQ-52
CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection.
Although the AD53032 features proprietary ESD protection circuitry, permanent damage may
occur on devices subjected to high energy electrostatic discharges. Therefore, proper ESD
precautions are recommended to avoid performance degradation or loss of functionality.
WARNING!
ESD SENSITIVE DEVICE
–6–
REV. 0