CV
2-(3). Electrical life (Lamp load)
Tested sample: ACV31212
Quantity: n = 5
Load: 120W, Inrush 80A, Steady 10A, 14V DC
Operating frequency: ON 2s, OFF 13s
Ambient temperature: Room temperature
10
8
Contact welding: 0 times
Miscontact: 0 times
Pick-up voltage
Max.
X
6
Min.
Circuit:
Tested sample
4
Drop-out voltage
Max.
2
X
Min.
120W
0
0
10
No. of operations, × 104
NOTES
1. Coil operating power
5. Usage, transport and storage
conditions
1) Ambient temperature, humidity, and
atmospheric pressure during usage,
transport, and storage of the relay:
(1) Temperature:
3) Freezing
Pure DC current should be applied to the
coil.The wave form should be rectangular.
If it includes ripple, the ripple factor should
be less than 5%. However, check it with
the actual circuit since the characteristics
may be slightly different.
Condensation or other moisture may
freeze on the relay when the
temperatures are lower than 0°C 32°F.
This causes problems such as sticking of
movable parts or operational time lags.
4) Low temperature, low humidity
environments
–40 to +85°C –40 to +185°F
(2) Humidity: 5 to 85% RH
2. Voltage applied to coil
(Avoid freezing and condensation.)
The humidity range varies with the
temperature. Use within the range
indicated in the graph below.
The plastic becomes brittle if the relay is
exposed to a low temperature, low
humidity environment for long periods of
time.
To ensure reliable operation, please apply
nominal voltage to the coil. Beware of the
fact that pick-up voltage and drop-out
voltage vary depending on the ambient
temperature and conditions.
6. Others
Humidity, %R.H.
1) If in error the relay has been dropped,
the appearance and characteristics
should be checked before use without fail.
2) Please do not use the coating material
of organic system which contains solvents
such as xylene and toluene for this
product.
3. Operating life
85
Operating life varies depending on the
type and load of the coil drive circuit, as
well as factors like the operating
frequency, operating phase and ambient
atmosphere, so please check with actual
equipment.
Tolerance range
(Avoid freezing when
(Avoid
used at temperatures
condensation when
used at temperatures
higher than 0°C 32°F)
lower than 0°C 32°F)
4.Soldering
5
We recommend the following soldering
conditions.
–40
–40
0
+32
+85
+185
Temperature, °C °F
1) Automatic soldering
(3) Atmospheric pressure: 86 to 106 kPa
2) Condensation
* Preheating: 100°C 212°F, within 2 mins
(PC board solder surface)
* Soldering: 260°C 500°F, within 5 s
2) Hand soldering
* Iron tip temperature: 280 to 300°C 536
to 571°F
Condensation forms when there is a
sudden change in temperature under high
temperature and high humidity conditions.
Condensation will cause deterioration of
the relay insulation.
* Soldering iron: 30 to 60W
* Soldering time: Within 5 s
12/1/2001
4
All Rights Reserved, © Copyright Matsushita Electric Works, Ltd.
Go To Online Catalog