ACA 3100E-B
wall mount receptacle
for front panel mounting
•
•
•
Receptacle with cable clamp and telescopic bushing
Includes grommet and grommet sleeve
Four through mounting holes or optional metric threaded holes
M
K
2
T
THRU HOLE
R
S
A
N
B
1
T
1
L
R
S
THREAD
L
Inches
2
T
A
M
+ .016
– .000
Thru Hole
+ .004
1
Shell
Size
+ .000
B
K
L
L
N
R
S
– .006
Max.
± .008
.110
.126
.126
.126
.157
.157
.157
.157
.157
.157
.157
Max.
Max.
2.362
2.440
2.756
2.756
3.031
3.031
3.031
3.346
3.346
3.346
4.134
Max.
± .004
± .012
1.000
1.181
1.280
1.280
1.378
1.496
1.614
1.752
2.000
2.244
2.500
– .000
10SL
14S
16S
16
.717
.256
.354
.433
.433
.559
.622
.622
.843
.843
1.051
1.248
4.720
4.720
4.720
4.921
4.921
4.921
4.921
4.921
4.921
4.921
5.315
.559
.559
.559
.748
.748
.748
.748
.811
.811
.874
.874
.894
.717
.906
.126
.126
.126
.126
.126
.126
.126
.146
.146
.169
.169
.969
1.083
1.181
1.181
1.300
1.476
1.476
1.705
1.705
2.035
2.283
1.079
1.079
1.213
1.346
1.472
1.610
1.839
2.102
2.346
.969
.969
18
1.063
1.157
1.252
1.374
1.563
1.752
1.937
20
22
24
28
32
36
Millimeters
2
T
1
A
M
+ 0.4
– 0.0
T
Thru Hole
+ 0.1
– 0.0
1
Shell
Size
+ 0.00
B
Max.
K
L
L
N
R
S
± 0.3
Metric
Thread
– 0.15
18.2
24.6
27.4
27.4
30.8
34.2
37.4
40.9
46.7
53.4
59.6
± 0.2
2.8
3.2
3.2
3.2
4.0
4.0
4.0
4.0
4.0
4.0
4.0
Max.
120
120
120
125
125
125
125
125
125
125
135
Max.
Max.
22.7
27.5
30.0
30.0
33.0
37.5
37.5
43.3
43.3
51.7
58.0
± 0.1
18.2
23.0
24.6
24.6
27.0
29.4
31.8
34.9
39.7
44.5
49.2
10SL
14S
16S
16
6.5
60
14.2
14.2
14.2
19.0
19.0
19.0
19.0
20.6
20.6
22.2
22.2
25.4
30.0
32.5
32.5
35.0
38.0
41.0
44.5
50.8
57.0
63.5
M4
M4
M4
M4
M4
M4
M4
M5
M5
M5
M5
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.7
3.7
4.3
4.3
9.0
62
11.0
11.0
14.2
15.8
15.8
21.4
21.4
26.7
31.7
70
70
18
77
20
77
22
77
24
85
28
85
32
85
36
105
All dimensions for reference only.
16