Adjustable Frequency Buck or Buck-Boost Pre-Regulator with
2 LDOs, Window Watchdog Timer, and NPOR
A4409
ELECTRICAL CHARACTERISTICS – LINEAR REGULATOR (LDO) SPECIFICATIONS 1: Valid at 3 V ≤ VIN ≤ 36 V in buck-
boost mode and VIN having first reached VIN(START), –40ºC ≤ TA = TJ ≤ 150ºC, unless otherwise specified.
Characteristic
V5 LINEAR REGULATOR
V5 Accuracy and Load Regulation
V5 Dropout
Symbol
Test Conditions
Min.
Typ.
Max.
Unit
VV5
10 mA ≤ IV5 ≤ 200 mA, VVREG = 5.4 V
4.9
4.75
1
5
–
–
5.1
–
V
V
VV5(DROPOUT)
CV5(OUT)
IV5 = 200 mA, VVLDO = 4.91 V
V5 Output Capacitance Range2
V5 OVERCURRENT PROTECTION
V5 Current Limit1
22
µF
IV5(LIM)
IV5(FB)
VV5 = 5 V
VV5 = 0 V
−230
−80
−325
−120
–
mA
mA
V5 Foldback Current1
−160
V5 STARTUP
V5 Startup Time2
tV5(START)
CV5 ≤ 2.9 µF, load = 25 Ω ±5% (200 mA)
–
0.24
1
ms
5V0 LINEAR REGULATOR
5V0 Accuracy and Load Regulation
5V0 Dropout
V5V0
10 mA ≤ I5V0 ≤ 300 mA, VVREG = 5.4 V
4.9
4.75
1
5
–
–
5.1
–
V
V
V5V0(DROPOUT) I5V0 = 300 mA, VVLDO = 4.91 V
C5V0(OUT)
5V0 Output Capacitance Range2
5V0 OVERCURRENT PROTECTION
5V0 Current Limit1
22
µF
I5V0(LIM)
I5V0(FB)
V5V0 = 5 V
V5V0 = 0 V
−345
−100
−485
−165
–
mA
mA
5V0 Foldback Current1
5V0 STARTUP
−230
5V0 Startup Time2
t5V0(START)
C5V0 ≤ 2.9 µF, load = 20 Ω ±5% (250 mA)
–
0.24
1
ms
1 Negative current is defined as coming out of the node or pin (sourcing), positive current is defined as going into the node or pin (sinking).
2 Ensured by design and characterization, not production tested.
Allegro MicroSystems, LLC
115 Northeast Cutoff
8
Worcester, Massachusetts 01615-0036 U.S.A.
1.508.853.5000; www.allegromicro.com