A43L2616B
AC Operating Test Conditions
(VDD = 3.3V ±0.3V, TA = 0°C to +70°C or TA = -40ºC to +85ºC)
Parameter
Value
AC input levels
VIH/VIL = 2.4V/0.4V
1.4V
Input timing measurement reference level
Input rise and all time (See note3)
Output timing measurement reference level
Output load condition
tr/tf = 1ns/1ns
1.4V
See Fig.2
3.3V
VOH(DC) = 2.4V, IOH = -2mA
VOL(DC) = 0.4V, IOL = 2mA
VTT =1.4V
1200Ω
50Ω
Output
ZO=50Ω
OUTPUT
50pF
870Ω
50pF
(Fig. 2) AC Output Load Circuit
(Fig. 1) DC Output Load Circuit
AC Characteristics
(AC operating conditions unless otherwise noted)
-6
-7
Unit
Note
Symbol
tCC
Parameter
CAS Latency
Min
6
Max
Min
7
Max
3
2
3
2
3
2
CLK cycle time
1000
1000
ns
ns
1
10
-
10
-
5
6
6
6
tSAC
CLK to valid Output delay
1,2
-
-
2.5
3
3
tOH
tCH
Output data hold time
CLK high pulse width
-
-
-
-
ns
ns
2
3
3
2.5
3
tCL
tSS
CLK low pulse width
Input setup time
2.5
1.5
1
-
-
-
3
2
1
-
-
-
ns
ns
ns
ns
3
3
3
2
tSH
tSLZ
Input hold time
CLK to output in Low-Z
1
-
-
1
-
-
3
2
5
6
6
6
tSHZ
CLK to output In Hi-Z
ns
-
-
*All AC parameters are measured from half to half.
Note : 1. Parameters depend on programmed CAS latency.
2. If clock rising time is longer than 1ns, (tr/2-0.5) ns should be added to the parameter.
3. Assumed input rise and fall time (tr & tf) = 1ns.
If tr & tf is longer than 1ns, transient time compensation should be considered,
i.e., [(tr + tf)/2-1]ns should be added to the parameter.
(December, 2009, Version 1.3)
6