I/O Mo d u le s  
segments. The minimum horizontal segment length is the  
width of a module-pair, and the maximum horizontal  
segment length is the full length of the channel. Any segment  
that spans more than one-third the row length is considered a  
long horizontal segment. A typical channel is shown in  
Figure 6. Non-dedicated horizontal routing tracks are used to  
route signal nets. Dedicated routing tracks are used for the  
global clock networks and for power and ground tie-off  
tracks.  
The I/O modules provide the interface between the device  
pins and the logic array (shown in Figure 5). A variety of I/O  
configurations, determined by a library macro selection, can  
be implemented in the module (refer to the Macro Library  
Guide for more information). I/O modules contain input and  
output latches as well as a tri-state buffer. These features  
allow the module to be configured for input, output, or  
bi-directional pins.  
Vertical Routing  
EN  
Other tracks run vertically through the module. Vertical  
tracks are of three types: input, output, and long. Vertical  
tracks are also divided into one or more segments. Each  
segment in an input track is dedicated to the input of a  
particular module. Each segment in an output track is  
dedicated to the output of a particular module. Long segments  
are uncommitted and can be assigned during routing. Each  
output segment spans four channels (two above and two  
below), except near the top and bottom of the array where  
edge effects occur. An example of vertical routing tracks and  
segments is shown in Figure 6.  
Q
D
PAD  
From Array  
G/CLK*  
Q
D
To Array  
Segmented  
Logic  
G/CLK*  
horizontal  
Modules  
routing  
tracks  
* Can be configured as a Latch or D Flip-Flop  
(using C-module)  
Figure 5 I/O Module  
Antifuses  
I/O modules contain input and output latches for capturing  
data prior to and/or from the device pins. In addition, the  
Actel Designer Series software tools can build a D flip-flop  
using a C-module in conjunction with the I/O latch to register  
input and/or output signals. Actel’s Designer Series  
development tools provide a design library of I/O macros  
which can implement all I/O configurations supported by the  
3200DX.  
Vertical routing tracks  
Figure 6 Horizontal Routing Tracks and Segments  
Antifuse Structures  
R o u t in g S t r u c t u r e  
An antifuse is a “normally open” structure as opposed to the  
normally closed fuse structure used in PROMs or PALs. The  
use of antifuses to implement a Programmable Logic Device  
results in highly testable structures as well as efficient  
programming algorithms. The structure is highly testable  
because there are no pre-existing connections; therefore,  
temporary connections can be made using pass transistors.  
These temporary connections can isolate individual antifuses  
to be programmed as well as isolate individual circuit  
structures to be tested. This can be done both before and after  
programming. For example, all metal tracks can be tested for  
continuity and shorts between adjacent tracks, and the  
functionality of all logic modules can be verified.  
The 3200DX architecture uses Horizontal and Vertical  
routing tracks to interconnect the various logic and I/O  
modules. These routing tracks are metal interconnects that  
may either be of continuous length or broken into pieces  
called segments. Varying segment lengths allows the  
interconnect of over 90% of design tracks to occur with only  
two antifuse connections. Segments can be joined together at  
the ends, using antifuses, to increase their lengths up to the  
full length of the track. All interconnects can be  
accomplished with a maximum of four antifuses.  
Horizontal Routing  
Horizontal channels are located between the rows of modules  
and are composed of several routing tracks. The horizontal  
routing tracks within the channel are divided into one or more  
6
 
 

与A32400DX-2BGG313I相关器件

型号 品牌 描述 获取价格 数据表
A32400DX-2PQG240C ACTEL Field Programmable Gate Array, 2526 CLBs, 40000 Gates, CMOS, PQFP240, PLASTIC, QFP-240

获取价格

A32400DX-2RQ240C ETC Field Programmable Gate Array (FPGA)

获取价格

A32400DX-2RQ240I ETC Field Programmable Gate Array (FPGA)

获取价格

A32400DX-2RQG240C ACTEL Field Programmable Gate Array, 5020 CLBs, 40000 Gates, CMOS, PQFP240, HEAT SINK, POWER, PL

获取价格

A32400DX-3RQ240C ETC Field Programmable Gate Array (FPGA)

获取价格

A32400DX-3RQ240I ETC Field Programmable Gate Array (FPGA)

获取价格