A22TK
Specifications
Approved Standard Ratings
• UL, cUL (File No. E41515): 6 A at 220 VAC, 10 A at 110 VAC
• TÜV (EN60947-5-1) (Low Voltage Directive): 3 A at 220 VAC
• CCC (GB14048.5): 3 A at 240 VAC, 1.5 A at 24 VDC
Certified Standards
Certification body
Standards
File No.
UL *1
UL508, C22.2 No.14
E41515
EN60947-5-1
(certified direct opening mechanism)
TÜV SÜD
Inquire
CQC(CCC)
KOSHA
GB14048.5
2003010303070635
2009-156
EN60947-5-1
Note: Only models with NC contacts have a direct opening mechanism.
*1. UL-certification for CSA C22.2 No. 14 and bears the
mark.
Ratings
Contacts (Standard load)
Rated current (A)
AC12 DC13
Rated carry current Rated voltage
AC15
DC12
(A)
(V)
(inductive load) (resistive load) (inductive load) (resistive load)
24 VAC
110
10
5
10
10
6
220
3
-
-
380
2
3
440
1
2
10
24 VDC
110
1.5
0.5
0.2
0.1
10
2
-
-
220
0.6
0.2
380
Note: 1. Rated current values are determined according to the testing conditions. The above ratings were obtained by conducting tests under the
following conditions.
(1) Ambient temperature: 20 2C°
(2) Ambient humidity: 65 5ꢀ RH
(3)Operating frequency: 20 operations/minute
2. Minimum applicable load: 10 mA at 5 VDC
Characteristics
Item
Model
A22TK
Mechanical
Electrical
30 operations/minute max.
30 operations/minute max.
100 MΩ min. (at 500 VDC)
Allowable operating
frequency
Insulation resistance
Between terminals
of same polarity
2,500 VAC, 50/60 Hz for 1 min.
2,500 VAC, 50/60 Hz for 1 min.
Dielectric strength
Between each
terminal and ground
Vibration resistance *1
Shock resistance
10 to 55 Hz, 1.5-mm double amplitude (within 1 ms)
1000 m/s2
Destruction
Malfunction *1
Mechanical
Electrical
250 m/s2 max.
100,000 operations min.
100,000 operations min.
-20 to +70°C
35ꢀ to 85ꢀRH
-40 to +70°C
IP65 *3
Durability
Ambient operating temperature *2
Ambient operating humidity
Ambient storage temperature
Degree of protection
Electric shock protection class
PTI (tracking characteristic)
Degree of contamination
Class II
175
3 (EN60947-5-1)
*1. Malfunction within 1 ms.
*2. With no icing or condensation.
*3. The degree of protection from the front of the panel.
Note: 1. Do not allow the load current to exceed the rated value.
2. The contact ON/OFF timing is not synchronized. Confirm performance before application.
3. Once the contacts have been used to switch a load, however, they cannot be used to switch smaller loads. The contact surfaces will
become rough once they have been used and contact reliability for smaller loads may be reduced.
7