Signal Relays
AXICOM
FT2/FU2 Relay
n
n
n
n
n
n
Telecom/signal relay (dry circuit, test access, ringing)
Slim line 15x7.5mm (.59x.295”)
Switching current 2A
2 form C bifurcated contacts (2 CO)
High sensitive 24V and 48V coil versions
Meets Telcordia GR 1089, FCC Part 68 and ITU-T K20, ≥ 2500V
between coil and contacts
Typical applications
Communications equipment, linecard application – analog, ISDN, xDSL,
PABX, voice over IP, office and business equipment, measurement and
control equipment, consumer electronics, set top boxes, HiFi, medical
equipment
Z
Approvals
Coil Data
UL 508 File No. E 111441
Technical data of approved types on request
Magnetic system
Coil voltage range
Max. coil temperature
Thermal resistance
monostable, non polarized
3 to 48VDC
150°C
<125K/W
Contact Data
Contact arrangement
Max. switching voltage
Rated current
2 Form C (CO)
220VDC, 250VAC
2A
Coil versions, monostable
Coil
code
Rated
voltage
VDC
Operate Limiting Release
Coil
Rated coil
Limiting continuous current
Switching power
Contact material
2A
voltage
voltage
voltage resistance power
VDCmin. VDCmax. VDCmin. Ω 10ꢀ
60W, 62.5VA
PdRu, Au covered
twin contacts
100µV/1µA
<70mΩ
<10µV
typ. 3ms, max. 5ms
mW
Standard version, monostable
Contact style
21
29
22
23
24
25
26
27
28
3
4
4.5
5
6
9
12
24
48
2.25
3.00
3.38
3.75
4.50
6.75
9.00
18.00
36.00
6.80
9.00
0.30
0.40
0.45
0.50
0.60
0.90
1.20
2.40
4.80
45
80
200
200
200
200
200
200
200
240
240
Min. recommended contact load
Initial contact resistance
Thermoelectric potential
Operate time
10.10
11.20
13.50
20.30
27.00
47.50
95.00
101
125
180
405
720
2400
9600
Release time
without diode in parallel
with diode in parallel
Bounce time max.
typ. 2ms, max. 5ms
typ. 4ms, max. 5ms
typ. 1ms, max. 5ms
Electrical endurance
at contact application 0
(≤ 30mV/≤10mA)
cable load open end
resistive, 24V / 1.25A - 30W
resistive, 30VDC / 2A - 60W
resistive, 125VDC / 0.24A - 30W
Contact ratings, UL contact rating
High dielectric version, monostable
91
92
93
96
97
3
4.5
5
12
24
2.25
3.38
3.75
9.00
18.00
6.80
10.10
11.20
27.00
47.50
0.30
0.45
0.50
1.20
2.40
45
101
125
720
2400
200
200
200
200
240
min. 2.5x106 operations
min. 2.0x106 operations
min. 1x105 operations
min. 1x105 operations
min. 1x105 operations
220VDC, 0.24A, 60W
125VDC, 0.24A, 30W
250VAC, 0.25A, 62.5VA
125VAC, 0.5A, 62.5VA
30VDC, 2A, 60W
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Other coil voltages on request.
2.6
200 mW coil
240 mW coil
2.4
2.2
Umax. at 0 A
Umax. at 2 x 1 A
Umax. at 2 x 2 A
Mechanical endurance
100x106 operations
2
1.8
Max. DC load breaking capacity
1.6
1.4
1.2
1
Unom. nominal coil voltage
0.8
0.6
Uop. min.
Urel. min.
0.4
0.2
0
-60 -50 -40 -30 -20 -10
0
10 20 30 40 50 60 70 80 90 10 11 12 13 14
0
0
0
0
0
Ambient Temperature [°C]
DC current [A]
1
01-2016, Rev. 0116
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
www.te.com
© 2015 Tyco Electronics Corporation,
a TE Connectivity Ltd. company