316L SS Pressure Sensor
Model 86 UltraStable
PERFORMANCE SPECIFICATIONS
All parameters specified at 1.5mA and at 25°C, after 10 second warm up, unless otherwise indicated. Unless specifically indicated, only those parameters
indicated as tested are verified on each part. Parameters are specified for the compensated version only.
PARAMETERS
MIN
75
TYP
100
0
MAX
150
1
UNITS
mV
NOTES
Full Scale Output Span
1
2
3
Zero Pressure Output (Offset)
Pressure Non Linearity
Pressure Hysteresis
–1
mV
–0ꢀ10
–0ꢀ05
0ꢀ10
+0ꢀ05
% Span
% Span
% Span
Ω
0ꢀ02
0ꢀ02
3500
Repeatability
Input Resistance
2000
4000
–0ꢀ75
–0ꢀ5
4500
25000
+0ꢀ75
+0ꢀ5
Output Resistance
Ω
Temperature Error - Span (–20 to +85°C)
Temperature Error - Offset (–20 to +85°C)
Thermal Hysteresis - Span
Thermal Hysteresis - Offset
Long Term Stability - Span
Long Term Stability - Offset
Supply Current
% Span
% Span
% Span
% Span
% Span/year
% Span/year
mA
4
4, 5
4
0ꢀ05
0ꢀ05
0ꢀ1
4
0ꢀ1
0ꢀ5
5
1ꢀ5
2ꢀ0
3X
6
7
8
Output Load Resistance
Insulation Resistance (50 VDC)
Pressure Overload
MΩ
50
MΩ
Rated
Compensated Temperature Range
Operating Temperature Range
Storage Temperature Range
Media - Pressure Port
–20°C to +85°C
–40°C to +125°C
–50°C to +125°C
9
9
9
Liquids and Gases compatible with 316L Stainless Steel
Compatible with Silicon, Pyrex, Gold, Fluorosilicone Rubber and
316L Stainless Steel
Media - Reference Port
Weight
13 g
Notes
1ꢀ For amplified output circuits see application note TN-003ꢀ
2ꢀ Measured at vacuum for absolute (A), ambient for gage (G)ꢀ
3ꢀ Best fit straight lineꢀ
6ꢀ Guarantees output/input ratiometricityꢀ
7ꢀ Load resistance to reduce measurement errors due to output loadingꢀ
8ꢀ Between case and sensing elementꢀ
4ꢀ Over the temperature range –20°C to +85°C with respect to +25°Cꢀ
9ꢀ Maximum temperature range for product with standard cable and
connector is –20°C to +105°Cꢀ
5ꢀ 15 psi range sensors have an offset temperature error of 0ꢀ75%
(Max) from –20°C to +85°Cꢀ
10ꢀ For gage units used at pressures below atmosphere, the span accuracy
is not guaranteedꢀ
ORDERING INFORMATION
APPLICATION SCHEMATIC
6
CONNECTIONS
PAD/CONDUCTOR NO
FUNCTION
+OUT
-EX
1
2
3
4
5
6
+EX
-OUT
GAIN
GAIN
June 2001
Feel free to contact customer service with any questions at
Toll free 1(800)745-8008; Phone (757)766-1500; Fax (757)766-4297
ISO – Wide Temperature Range
1-71