 浏览型号85-100G-8R的Datasheet PDF文件第1页 
316L SS Pressure Sensor  
Model 85 UltraStable  
PERFORMANCE SPECIFICATIONS  
All parameters measured at 1.5mA drive and at 25°C after 10 second warm up, unless otherwise specified. Unless specifically indicated, only those parameters  
indicated as tested are verified on each part. Parameters are specified for the compensated version only.  
PARAMETERS  
MIN  
75  
TYP  
100  
0
MAX  
150  
UNITS  
mV  
NOTES  
Full Scale Output Span  
Zero Offset  
1, 2  
2
-1  
1
mV  
Pressure Non-linearity  
Pressure Hysteresis  
-0.10  
-0.05  
2,000  
4000  
-0.75  
-0.5  
0.10  
0.05  
4,500  
25000  
0.75  
0.5  
% Span  
% Span  
3
0.02  
Input Resistance  
3,500  
Output Resistance  
Temperature Error - Span  
Temperature Error - Zero  
Thermal Hysteresis - Span  
Thermal Hysteresis - Zero  
Long Term Stability - Offset  
Long Term Stability - Span  
Supply Current  
% Span  
% Span  
% Span  
% Span  
% Span/yr.  
% Span/yr.  
mA  
4
4, 5  
4
0.05  
0.05  
0.1  
4
0.1  
0.5  
5
1.5  
2.0  
3X  
6
7
8
Output Load Resistance  
Insulation Resistance (50 VDC)  
Pressure Overload  
M  
50  
MΩ  
Rated  
Compensated Operating Temperature  
Operating Temperature Range  
Storage Temperature Range  
Media - Pressure Port  
–20°C to +85°C  
–40°C to +125°C  
–50°C to +125°C  
9
9
9
Liquids and Gases compatible with 316L Stainless Steel  
Compatible with Silicon, Pyrex, Gold, Fluorosilicone Rubber and  
316L Stainless Steel  
Media - Reference Port  
Weight  
13 g  
10  
Notes  
1. For amplified output circuits, 3.012V  
1% interchangeability with gain  
7. Load resistance to reduce measurement errors due to output loading.  
8. Between case and sensing element.  
set resistor. See Application Note TN-003.  
2. Measured at vacuum for absolute (A), ambient for gage (G).  
3. Best fit straight line.  
9. Maximum temperature range for product with standard cable and  
connector is –20°C to +105°C.  
4. Over Temperature range: -20°C to +85°C Span with respect to +25°C.  
10. Weight depends upon configuration (cable, connector, pressure fitting).  
5. 15 psi range sensors have a temperature error of 0.75% (Max) of  
Zero from -20°C to 85°C.  
11. For gage units used at pressures below atmosphere, the span accuracy  
is not guaranteed.  
6. Guarantees output/input ratiometricity.  
ORDERING INFORMATION  
APPLICATION SCHEMATIC  
CONNECTIONS  
PAD NO. / CABLE  
FUNCTION  
+OUT  
-EX  
1
2
3
4
5
6
+EX  
-OUT  
GAIN  
GAIN  
October 2001  
Feel free to contact customer service with any questions at  
Toll free 1(800)745-8008; Phone (757)766-1500; Fax (757)766-4297  
ISO – Wide Temperature Range  
1-69  

与85-100G-8R相关器件

型号 品牌 描述 获取价格 数据表
85-100G-8RT ETC Signal Conditioner

获取价格

851-00RA12-3S5002 AMPHENOL CONNECTOR, 3 CONTACT(S), ALUMINUM, FEMALE, CIRCULAR ADAPTER

获取价格

851-00RA12-8S50031 AMPHENOL CONNECTOR, 8 CONTACT(S), ALUMINUM, FEMALE, CIRCULAR ADAPTER

获取价格

851-00RA14-12P50 AMPHENOL CONNECTOR, 12 CONTACT(S), ALUMINUM, MALE, CIRCULAR ADAPTER

获取价格

851-00RA14-12P5002 AMPHENOL CONNECTOR, 12 CONTACT(S), ALUMINUM, MALE, CIRCULAR ADAPTER

获取价格

851-00RA14-15P5002 AMPHENOL CONNECTOR, 15 CONTACT(S), ALUMINUM, MALE, CIRCULAR ADAPTER

获取价格