6
Control up to 16 Instruments Over LAN Connections
- PC Application -
LOGGER COMMUNICATOR 9334 (optional software)
Collect Data on a PC via Ethernet
Data from a HiLOGGER connected to a LAN can be stored on the hard disk of a PC in real time. Other functions include waveform
display, CSV conversion, printing, numerical value calculations and searching.
A
t a b l e s h o w s t i m e
Acquired data (either all data, or only that between
marker cursors) can be converted to CSV format
text data. Data in this format can be loaded into a
spreadsheet program such as Excel.
difference and potential
difference between A and
B cursors, and the time and
potential at each cursor on
the waveform screen.
A c q u i r e d d a t a c a n b e
displayed as numerical values
for time series’. Waveform
i m a g e a n d n u m e r i c a l
values can be displayed
simultaneously.
A c q u i r e d d a t a c a n
be pr inte d out a s a
waveform image on a
connected printer.
Acquired data can be
subjected to parameter
calculations such as
maximum value, time
and average value.
The waveform image of acquired
data is displayed. It can be drawn
in real time during data acquisition.
Up to 512 analog channels, 256
logic channels and 64 pulse
channels are supported.
Acquired data can be
searched for specific
event marks, as well
as for conditions such
as date, maximum and
minimum values.
Specification Overview
■
(PC application, sold separately)
LOGGER COMMUNICATOR 9334
Interface: Ethernet Controllable instruments: 16 Data
■
■
■
transfer: data transferred from instrument's internal memory,
data acquired in real time Display: displays image of
■
acquired waveform data on-screen, real-time data image during
acquisition, numerical values, and simultaneous display of
Functions
image and numerical values Maximum channels: 512 analog,
■
256 logic and 64 pulse channels Data conversion: converts
■
all data or data between AB cursors to CSV-format text data
■
Printing: available Parameter calculation: available Other
■
■
functions: marking function, search function
Windows 95/98/Me, Windows NT 4.0 (SP3 or later), 2000, XP
PC operating systems
■ Product Specifications
One internal delta-sigma type A/D converter with digital filtering
A/D Converter
General Specifications
(push-button type terminal block)
Trigger input, trigger output
External control connectors
8420-51/8421-51
Temperature (thermocouple, Pt), Temperature (ther mocouple
voltage, humidity, totalized only), voltage, totalized pulses,
8422-51
Time and settings: 10 years or more,
Measurement
parameters
Memory backup
function (@23˚C)
10 minutes or more after turning
instrument power off (Retained from at least 2 minutes after power on)
Measurement data:
pulses, rotation count
rotation count
Operating temperature and humidity: 0 (32˚F) to 40˚C (104˚F), 30 to 80% rh
Environmental
Analog: 8 channels isolated by
Photo-MOS relays/16 channels
charging temperature range: 10
(
to 30 C
˚ (86˚F))
(32˚F)
conditions
Analog: 32 channels isolated by
(non-condensating)
Storage temperature and humidity: -10 (14˚F) to 50˚C (122˚F), 30 to 80% rh
Photo-MOS relays (voltage and
scanning isolated inputs (voltage,
temperature can be independently selected
temperature and humidity independently
Input System/
Channels
Safety: EN61010, EMC: EN61326, EN61000
Conforming standards
Power supply
for each channel)
selectable for each channel)
Pulse Inputs: 4 channels
-15
(1) Using the
, 100 to 240 VAC, 50/60 Hz
AC ADAPTER 9418
Pulse Inputs: 4 channels
Logic Inputs: 16 channels (using
the DIGITAL I/O UNIT 8993)
(when used with the AC ADAPTER, the AC
(2) The
BATTERY PACK 9447
Logic Inputs: 16 channels (using
the DIGITAL I/O UNIT 8993)
ADAPTER has priority)
(voltage may range from 30 to 20%, although chargeable range is
+
−
(3) 12 V Battery
12 VDC 5%)
±
(5 s to 1 hour when
(200 ms to 1 hour
100 ms to 1 hour
100 ms to 1 hour
Recording
intervals
combined with humidity measurement) when using channels 17 to 32)
(maximum load under battery power)
(maximum load using AC Adapter)
, 20 VA
16 VA
Power consumption
Continuous usage time
with one Model 9447 BATTERY
PACK, when measuring voltage
Note: All input channels are scanned at high speed during each recording interval.
(with 5-min backlight saver setting, after about 10 hours charging)
(with bright backlight, after about 2.5 hours charging)
Approx. 5 hours
Approx. 2.5 hours
Data recording
capacity
(about 16.77 million data points: each data point = 2 bytes/16 bits)
(Flash ATA Card)
Internal: 32 MB
External: up to 1GB
Available withthe batterypackandAC Adapterconnected: quick
Waveforms are saved as binary data to the PC Card in real time, and
can be saved to separate files at preset times, selectable as full files
or an endless loop with automatic deletion of oldest data. Stored data
can be recalled by the instrument in 32-MB blocks by specifying a
Charging
Battery pack
(@23 C)
˚ , afterwhichtrickle charging
chargingtime isapprox. 2.5hours
preventsbatteryself-discharge. Printinginterruptsquickcharging.
Real time save
Approx. 234 mm (9.21 in) W × 170 mm (6.69 in) H × 52 mm (2.05 in) D mm, 1.4 kg (49.4 oz) (instrument only)
Approx. 310.5 (12.22 in) W × 170 (6.69 in) H × 52 (2.05 in) D mm, 1.7 kg (60.0 oz) (with printer attached)
Approx. 302.5 (11.91 in) W × 170 (6.69 in) H × 52 (2.05 in) D mm, 1.7 kg (60.0 oz) (with Digital I/O Unit)
(for one channel. For n channels, 32 MB / 2n data points are recalled.)
time point
Dimensions &
Mass (without battery)
PC Card type II slot: accepts Flash ATA (up to 1GB)
Stores binary data (custom format), text data (Excel format), BMP data
(screen images), numerical calculation results and measurement values.
A-B cursors can be used select data to be saved (manual operation only).
File operations
PC Interface
-15
1, Application disk 1 (Wave Viewer Wv,
AC ADAPTER 9418
Communication Commands Operating Manual), Flat-blade Screwdriver
( 1, for terminal block), Detailed Operating Manual 1, Communication
×
×
Accessories
×
×
(Round 9-pin mini-DIN connector)
RS-232C
Function/Wave Viewer Operating Manual 1, Quick Start Manual
1
×
×
(supports 10Base-T, DHCP, DNS)
LAN