Magnetic and Hydraulic-Magnetic Circuit Breaker 8330-...
Ordering information
Type No.
8330 circuit breaker
Mounting
8330 - G
M
1
0 -
P
B
BS - A
Paddle, Baton, Button
F
flange, black
threadneck, black
flange, grey
snap-in, black
flange, white
Size
1
2
3
4
6
7
8
green
white
black
blue
yellow
red
orange
G
Q
M
N
G
M
N
S
panel thickness 1 -2.5 mm (flange)
1/2“-32 for actuator B, C, M, P, 1 and 3
3/8”-32 for actuator D and 5
standard fuseholder cut out for mounting -M only
Number of poles
Illumination voltage
A 120 V, 250 V, neon, external resistor
B 120V, 250V, green, neon,
external resistor
1
2
single pole
double pole
Panel hardware (bulk)
C LED red, external resistor
D LED green, external resistor
E LED amber, external resistor
X no illumination
Auxiliary contacts
0
9
without (1 hex nut, threadneck only)
rocker guard
E
F
H
1 hex, 1 knurled (Ni) threadneck only
1 hex, 1 knurled (Ni), legend plate, threadneck only
1 hex, 1 knurled (Ni), locking ring, legend plate,
threadneck only
1 hex, 1 knurled with collar (Ni), threadneck only
1 hex, 1 knurled with collar (Ni), legend plate,
threadneck only
1 hex, 1 knurled with collar (Ni), locking ring,
legend plate, threadneck only
Terminal design
A
J
without auxiliary contacts
1 changeover, 1st pole,
.06 dia solder turret
1 changeover 1st pole,
-058 dia round QC
K
N
P
Internal circuit
A
B
switch only
series trip
Not used
00
R
J
P
X
screw terminal, 8-32, with upturned lugs
blade terminal 6.3 mm
Frequency
4
AC 50/60 Hz
DC
9
screw terminal, 8-32 (bus type)
M
AC + DC
W push-in stud
4
Current rating
0.1...30 A
Approvals
Actuator configuration
B
C
D
E
paddle, without legend plate
baton, without legend plate
push to reset, no button marking
dual colour rocker (legend vertical)
»ON« indication
A
E
without
UL1077,
CSA, TÜV
G
dual colour rocker (legend vertical)
»OFF«indication
8330 - G
M
1
0 -
P
B
BS - 2 X A
B
00 4 - 5A - ... ordering example
K
M
P
R
T
W
1
3
flat rocker (legend vertical) illuminated
paddle, legend plate ON-OFF vertical
paddle, legend plate I-0 vertical
rocker (legend vertical)
flat rocker (legend vertical)
rocker illuminated (vertical)
baton, legend plate ON-OFF vertical
baton, legend plate I-0 vertical
push pull, rated Amps horizontal
Characteristic curve
Standard current ratings and typical internal resistance values
Current rating (A)
Internal resistance (Ω) per pole
0.1
0.25
0.5
0.75
1
103
5
20
3.8
00
switch only
BD
BS
CD
CS
OP
medium AC/DC
medium
short AC/DC
short
instantaneous
1.5
1
2
0.26
0.11
0.041
0.023
0.01
< 0.01
< 0.01
< 0.01
< 0.01
< 0.01
3
Actuator colour and marking details
Rocker not illuminated
5
A
K
L
green
white
black
blue
I-0
I-0
I-0
I-0
I-0
I-0
I-0
I-0
ON-OFF
ON/OFF
ON-OFF
ON-OFF
ON-OFF
ON-OFF
ON-OFF
ON-OFF
7.5
10
12.5
15
20
25
30
V
W gray
X
Y
Z
yellow
red
orange
Rocker illuminated
clear
red transparent
green transparent
T
U
V
I-0
I-0
I-0
I-0
ON-OFF
ON/OFF
ON-OFF
ON-OFF
ON-OFF
ON-OFF
W amber transparent
X
Y
smoke gray transparent I-0
white translucent I-0
8330 - G
M
1
0 -
P
B
BS - ...
mm
inch
This is a metric design and millimeter dimensions take precedence (
)
4 - 2
www.e-t-a.de
2013/14