5秒后页面跳转
7MBP75RTB060 PDF预览

7MBP75RTB060

更新时间: 2024-01-11 15:07:39
品牌 Logo 应用领域
富士电机 - FUJI 双极性晶体管
页数 文件大小 规格书
23页 960K
描述
IGBT - IPM

7MBP75RTB060 技术参数

生命周期:Active包装说明:,
Reach Compliance Code:unknownECCN代码:EAR99
HTS代码:8542.39.00.01风险等级:5.6
模拟集成电路 - 其他类型:AC MOTOR CONTROLLERJESD-30 代码:R-XXMA-X25
功能数量:1端子数量:25
最大输出电流:150 A封装主体材料:UNSPECIFIED
封装形状:RECTANGULAR封装形式:MICROELECTRONIC ASSEMBLY
认证状态:Not Qualified最大供电电压 (Vsup):16.5 V
最小供电电压 (Vsup):13.5 V标称供电电压 (Vsup):15 V
表面贴装:NO技术:HYBRID
端子形式:UNSPECIFIED端子位置:UNSPECIFIED
Base Number Matches:1

7MBP75RTB060 数据手册

 浏览型号7MBP75RTB060的Datasheet PDF文件第6页浏览型号7MBP75RTB060的Datasheet PDF文件第7页浏览型号7MBP75RTB060的Datasheet PDF文件第8页浏览型号7MBP75RTB060的Datasheet PDF文件第10页浏览型号7MBP75RTB060的Datasheet PDF文件第11页浏览型号7MBP75RTB060的Datasheet PDF文件第12页 
Vin(th)  
On  
Vin  
Ic  
Vin(th)  
trr  
90%  
50%  
90%  
ton  
10%  
toff  
Figure 1. Switching Time Waveform Definitions  
off  
off  
/Vin  
Vge (Inside IPM)  
Fault (Inside IPM)  
/ALM  
on  
on  
Gate On  
Gate Off  
normal  
alarm  
2ms(typ.)  
tALMMax.  
tALMMax.  
tALM  
FaultOver-current,Over-heat or Under-voltage  
Figure 2. Input/Output Timing Diagram  
Necessary conditions for alarm reset (refer to to in figure2.)  
This represents the case when a failure-causing Fault lasts for a period more than tALM.  
The alarm resets when the input Vin is OFF and the Fault has disappeared.  
This represents the case when the ON condition of the input Vin lasts for a period more  
than tALM. The alarm resets when the Vin turns OFF under no Fault conditions.  
This represents the case when the Fault disappears and the Vin turns OFF within tALM.  
The alarm resets after lasting for a period of the specified time tALM.  
off  
/Vin  
on  
Ioc  
on  
Ic  
alarm  
tdoc  
/ALM  
tdoc  
Figure 3. Over-current Protection Timing Diagram  
Period :  
Period :  
When a collector current over the OC level flows and the OFF command is input within  
a period less than the trip delay time tdoc, the current is hard-interrupted and no alarm  
is output.  
When a collector current over the OC level flows for a period more than the trip delay  
time tdoc, the current is soft-interrupted. If this is detected at the lower arm IGBTs,  
an alarm is output.  
a
9
MS6M 0653  
23  
H04-004-03  

与7MBP75RTB060相关器件

型号 品牌 描述 获取价格 数据表
7MBP75RTB-060 FUJI IGBT - IPM

获取价格

7MBP75RTB060_0307 FUJI IPM-R3

获取价格

7MBP75RTE060 FUJI Insulated Gate Bipolar Transistor, 75A I(C), 600V V(BR)CES, N-Channel

获取价格

7MBP75RTJ060 FUJI AC Motor Controller,

获取价格

7MBP75RTJ-060 ETC IGBTs

获取价格

7MBP75RU2A120 FUJI AC Motor Controller, 150A, Hybrid

获取价格