Philips Semiconductors
Product specification
14-stage binary ripple counter with oscillator
74LV4060
TIMING DIAGRAM
1
2
4
8
16
32
64
128
256
512
1.024 2.048 4.096
8.192 16.384
RS
MR
Q3
Q4
Q5
Q6
Q7
Q8
Q9
Q11
Q12
Q13
SV00309
1, 2
ABSOLUTE MAXIMUM RATINGS
In accordance with the Absolute Maximum Rating System (IEC 134)
Voltages are referenced to GND (ground = 0V)
SYMBOL
PARAMETER
DC supply voltage
CONDITIONS
RATING
–0.5 to +7.0
20
UNIT
V
V
CC
±I
IK
DC input diode current
DC output diode current
V < –0.5 or V > V + 0.5V
mA
mA
I
I
CC
±I
OK
V
O
< –0.5 or V > V + 0.5V
50
O
CC
DC output source or sink current
– standard outputs
±I
O
–0.5V < V < V + 0.5V
mA
O
CC
25
DC V or GND current for types with
–standard outputs
CC
±I
±I
,
mA
GND
50
CC
T
stg
Storage temperature range
–65 to +150
°C
Power dissipation per package
–plastic DIL
–plastic mini-pack (SO)
for temperature range: –40 to +125°C
above +70°C derate linearly with 12mW/K
above +70°C derate linearly with 8 mW/K
above +60°C derate linearly with 5.5 mW/K
750
500
400
P
TOT
mW
–plastic shrink mini-pack (SSOP and TSSOP)
NOTES:
1. Stresses beyond those listed may cause permanent damage to the device. These are stress ratings only and functional operation of the
device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to
absolute-maximum-rated conditions for extended periods may affect device reliability.
2. The input and output voltage ratings may be exceeded if the input and output current ratings are observed.
5
1998 Jun 23