SLOS181B − FEBRUARY 1997 − REVISED APRIL 2004
†
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, V
Supply voltage, V
(see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 V
(see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −19 V
CC+
CC−
Differential input voltage range, V (see Note 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V
Input voltage range, V (any input) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V
to V
to V
ID
CC+
CC+
CC−
CC−
I
Input current, I (each input) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 mA
I
Output current, I (each output) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 mA
O
Total current into V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160 mA
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160 mA
CC+
CC−
Total current out of V
Duration of short-circuit current at (or below) 25°C (see Note 3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . unlimited
Package thermal impedance, θ (see Notes 4 and 5): D package . . . . . . . . . . . . . . . . . . . . . . . . . . 97.1°C/W
JA
DW package . . . . . . . . . . . . . . . . . . . . . . . . 57.3°C/W
N package . . . . . . . . . . . . . . . . . . . . . . . . . . 79.7°C/W
P package . . . . . . . . . . . . . . . . . . . . . . . . . . 84.6°C/W
Package thermal impedance, θ (see Notes 4 and 5): FK package . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.6°C/W
JC
J package . . . . . . . . . . . . . . . . . . . . . . . . . . 15.1°C/W
JG package . . . . . . . . . . . . . . . . . . . . . . . . . 14.5°C/W
U package . . . . . . . . . . . . . . . . . . . . . . . . . . 14.7°C/W
W package . . . . . . . . . . . . . . . . . . . . . . . . . . . 10°C/W
Operating free-air temperature range, T : C suffix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C
A
I suffix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −40°C to 85°C
M suffix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −55°C to 125°C
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −65°C to 150°C
Case temperature for 60 seconds: FK package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds: DW or N package . . . . . . . . . . . . . . . 260°C
Lead temperature 1,6 mm (1/16 inch) from case for 60 seconds: J, JG, U, or W package . . . . . . . . . . 300°C
†
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. All voltage values, except differential voltages, are with respect to the midpoint between V
and V .
CC+
CC−
2. Differential voltages are at the noninverting input with respect to the inverting input.
3. The output may be shorted to either supply. Temperatures and/or supply voltages must be limited to ensure that the maximum
dissipation rate is not exceeded.
4. Maximum power dissipation is a function of T (max), θ , and T . The maximum allowable power dissipation at any allowable
J
JA
A
ambient temperature is P = (T (max) − T )/θ . Operating at the absolute maximum T of 150°C can affect reliability.
D
J
A
JA
J
5. The package thermal impedance is calculated in accordance with JESD 51-7 (plastic) or MIL-STD-883 Method 1012 (ceramic).
recommended operating conditions
C SUFFIX
I SUFFIX
M SUFFIX
UNIT
MIN
2.25
−0.9
−10.9
0
MAX
MIN
2.25
−0.8
MAX
MIN
2.25
−0.8
MAX
Supply voltage, V
CC
19
5
19
5
19
5
V
V
V
=
=
5 V
CC
Common-mode input voltage, V
IC
V
15 V
15 −10.8
70 −40
15 −10.8
85 −55
15
CC
Operating free-air temperature, T
125
°C
A
6