SCBS190F − JANUARY 1991 − REVISED SEPTEMBER 2003
†
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage range, V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to 7 V
CC
Input voltage range, V (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to 7 V
I
Voltage range applied to any output in the high or power-off state, V
. . . . . . . . . . . . . . . . . . . −0.5 V to 5.5 V
O
Current into any output in the low state, I : SN54ABT573 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96 mA
O
SN74ABT573A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128 mA
Input clamp current, I (V < 0) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −18 mA
IK
OK
I
Output clamp current, I
(V < 0) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −50 mA
O
Package thermal impedance, θ (see Note 2): DB package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70°C/W
JA
(see Note 2): DW package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58°C/W
(see Note 2): GQN/ZQN package . . . . . . . . . . . . . . . . . . . . . . . . . . . 78°C/W
(see Note 2): N package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69°C/W
(see Note 2): NS package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60°C/W
(see Note 2): PW package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83°C/W
(see Note 3): RGY package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37°C/W
Storage temperature range, T
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −65°C to 150°C
stg
†
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. The input and output negative-voltage ratings may be exceeded if the input and output clamp-current ratings are observed.
2. The package thermal impedance is calculated in accordance with JESD 51-7.
3. The package thermal impedance is calculated in accordance with JESD 51-5.
recommended operating conditions (see Note 4)
SN54ABT573 SN74ABT573A
UNIT
MIN
4.5
2
MAX
MIN
4.5
2
MAX
V
V
V
V
Supply voltage
5.5
5.5
V
V
CC
High-level input voltage
Low-level input voltage
Input voltage
IH
0.8
0.8
V
IL
0
V
0
V
CC
V
I
CC
I
I
High-level output current
Low-level output current
Input transition rise or fall rate
Operating free-air temperature
−24
48
−32
64
5
mA
mA
ns/V
°C
OH
OL
∆t/∆v
Outputs enabled
5
T
−55
125
−40
85
A
NOTE 4: All unused inputs of the device must be held at V
or GND to ensure proper device operation. Refer to the TI application report,
CC
Implications of Slow or Floating CMOS Inputs, literature number SCBA004.
3