110L...-PCB / 430L...-PCB Series
Signal conditioned precision pressure transducers
Specification notes:
1. The minimum supply voltage is directly proportional to the load resistance seen by the transmitter. For more details see the
load limitation diagram.
2. Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element.
3. The output signal is proportional to the pressure applied to port B, relative to port A, e.g. the output signal increases when
vacuum is applied to port A relative to port B.
4. Calibrated after minimum 3 minutes warm-up time.
5. Full scale span is the algebraic difference between the positive full scale output and the zero pressure offset.
6. Thermal effects tested and guaranteed from 0 - 50°C relative to 25°C. All specifications shown are relative to 25°C.
7. Non-linearity refers to the Best Straight Line fit measured for offset pressure, full scale pressure and 1/2 full-scale pressure.
8. Change in output after one year or 1 million pressure cycles.
OUTPUT CHARACTERISTICS
1...6 V output versions
Pressure/vacuum devices
113L...-PCB
1...6 V output versions
Differential devices
112L...-PCB
6
6
Vout
Vout
5
5
V
V
4
4
3.5 V
3
3
2
2
1
0
1
0
0
50
100
80 100
-100
-50
20 40 60
% full scale pressure
% full scale pressure
4...20 mA output versions
Differential devices
4...20 mA output versions
Pressure/vacuum devices
432L...-PCB
433L...-PCB
20
Iout
16
20
Iout
16
mA
mA
12
12
8
4
8
4
0
80 100
20 40 60
% full scale pressure
0
50
100
0
-50
-100
% full scale pressure
4/6
January 2007 / 006
www.sensortechnics.com