IMX35 Series Data Sheet
35 Watt Quad-Output DC-DC Converters
®
Table 17: Electric strength test voltages
Characteristic
Input to
Input to
Outputs to
case
Between
outputs
Unit
(outputs+case)
20/40IMX35 1
(outputs+case)
70/110IMX35 1
1
all models
all models
Factory test >1 s
1.2
1.5
1.8
2.5
0.5
0.7
0.152
0.22
kVAC
kVDC
Equivalent DC voltage
Insulation resistance
at 500 VDC
>100
>100
–
–
MΩ
1
For open-frame models (option Z), only the insulation input to outputs is tested.
The test voltage between outputs is not applied as routine test.
2
Isolation
60950 and should not be repeated in the field. Power-One will
not honor any warranty claims resulting from electric strength
field tests.
The electric strength test is performed in the factory as a
routine test in accordance with EN 50116, EN 60950, and UL
should be connected to Vi– to enable the output (active low
logic, fail safe).
Options
i: Inhibit (Negative Shutdown Logic)
Voltage at pin 8:
The outputs of the converter may be enabled or disabled by
means of a logic signal (TTL, CMOS, etc.) applied to the inhibit
pin 8. If the inhibit function is not required the inhibit (pin 8)
Converter operating:
Converter disabled:
–10 V to 0.8 V
2.4 V to 20 V or left
open-circuit
Z: Open Frame
06138a
For applications, where the protection by a housing is not
necessary or in the case that the motherboard should be
lacquered after fitting the converter.
4
8
2
Vi+
i
Note: The converters shall not be exposed to cleaning processes,
as this will damage the glue of the ferrite cores.
Vi–
G: RoHS-6
Fig. 19
If the inhibit pin is not used, connect it to Vi–.
Converters with a type designation ending by G are RoHS-
compliant for all six substances.
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical
components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written
consent of the respective divisional president of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on
the date manufactured. Specifications are subject to change without notice.
BCD20009-G Rev AC, 06-May-2013
Page 15 of 15