5秒后页面跳转
34931T PDF预览

34931T

更新时间: 2022-02-26 12:40:32
品牌 Logo 应用领域
是德科技 - KEYSIGHT /
页数 文件大小 规格书
35页 1600K
描述
Multifunction Switch/Measure Unit

34931T 数据手册

 浏览型号34931T的Datasheet PDF文件第28页浏览型号34931T的Datasheet PDF文件第29页浏览型号34931T的Datasheet PDF文件第30页浏览型号34931T的Datasheet PDF文件第32页浏览型号34931T的Datasheet PDF文件第33页浏览型号34931T的Datasheet PDF文件第34页 
31 | Keysight | 34980A Multifunction Switch/Measure Unit - Data Sheet  
General speciꢀcations  
Keysight BenchLink data logger features  
Power supply  
Universal 100 V to 240 V ± 10%  
50 – 60 Hz ± 10% automatically sensed  
150 VA  
Conꢀguration  
Spreadsheet-like channel conꢀgurations page.  
Power line frequency  
Power consumption  
Operating environment  
Upload and Download instrument conꢀgurations.  
Computed channels using + - */, dB, dBm, dBV,  
x2, x and full, ½ , or ¼ bridge strain  
Full accuracy for 0 °C to 55 °C  
Full accuracy to 80% R.H. at 40 °C  
IEC 60664-1 pollution degree 1  
–40°C to 70°C [1]  
Graphical Displays  
Real-time and historical data displays Add,  
delete, size, and conꢀgure real time Strip chart  
with markers and alarm indication, bar and  
scatter charts, Histogram with statistics, Bar  
meter, and Data table  
Storage environment  
Mainframe dimensions  
133 H x 426 W x 341 D mm (5.25" x 16.8" x 14")  
Full rack, 3 units high  
Graphical Controls  
Sliders, switches, buttons, and LED lights  
Mainframe weight  
Module dimensions  
Module weights  
8.8 kg (19.6 lbs)  
Alarm / Limit testing Start/Stop scanning on alarm condition  
Control 34903A relay state or 34907A digital  
output on alarm  
280 H x 170 W x 27 D mm (11" x 6.7" x 1")  
0.73 to 1.18 kg (1.6 to 2.6 lbs)  
Terminal block dimensions 28 H x 170 W x 114 D mm (1.1" x 6.7" x 4.5")  
Data  
Real time streamed (saved) to disk  
Automatically export data and conꢀgurations  
Copy data or graphics to windows clipboard  
Export your selected data to .CVS, .XML, or  
TXT formats  
Terminal block weights  
Safety conforms to  
EMC conforms to  
Warranty  
0.27 to 0.36 kg (0.6 to 0.8 lbs)  
CSA, UL/IEC/EN 61010-1  
IEC/EN 61326-1, CISPR 11  
1 year  
Event logging  
Automatic entry of alarms and errors  
Software  
[1] Storage at temperatures above 40 °C will decrease battery life  
Keysight connectivity software included  
[2] Load IO Libraries Version M for Windows NT support or version 14.0 for  
Keysight IO Libraries Suite 14 or greater (E2094)  
Minimum system requirements (IO libraries and drivers)  
Windows 98 SE support  
PC hardware  
Intel Pentium 100 MHz, 64 Mbyte RAM,  
210 Mbyte disk space  
Deꢁnitions for speciꢁcations  
Speciꢁcations describe the warranted performance of calibrated  
instruments that have been stored for a minimum of 2 hours  
within the operating temperature range of 0 °C to 50 °C, unless  
otherwise stated, and after a 45 minute warm-up period.  
Data represented in this document are speciꢁcations unless  
otherwise noted.  
Display 800 x 600, 256 colors, CD-Rom drive  
Operating system [2]  
Computer interfaces  
Windows 98 SE/NT/2000/XP  
Standard LAN 10BaseT/100BaseTx  
Standard USB 2.0  
IEEE 488.2 GPIB  
Software driver support for programming languages  
Software drivers: IVI-C and IVI COM for Windows NT/2000/  
XP LabVIEW  
Compatible with programming tools and environments:  
Keysight VEE Pro, Keysight T&M Toolkit  
Characteristics describe product performance that is useful in  
the application of the product, but that is not covered by the  
product warranty. Characteristics are often referred to as Typical  
or Nominal values.  
Typical describes characteristic performance, which 80% of  
instruments will meet when operated over a 20 °C to 30 °C  
temperature range. Typical performance is not warranted.  
Nominal describes representative performance that is  
useful in the application of the product when operated over  
a 20 °C to 30 °C temperature range. Nominal performance  
is not warranted.  
(requires Visual Studio.NET)  
National Instruments Test Stand,  
Measurement Studio, LabWindows/CVI,  
LabVIEW, Switch Executive  
Microsoft Visual Studio.NET, C/C++,  
Visual Basic 6  
Keysight BenchLink data logger software system requirements  
NOTE: All graphs contain measured data from several units at  
room temperature unless otherwise noted.  
Operating system:  
Controller:  
Windows 2000 SP4, XP SP 2  
Recommend Pentium 4, 800 MHz or greater,  
Min: Pentium III, 500 MHz  
RAM:  
Recommend 256 MB or greater, Min 128 MB  
Recommend 200 MB, Min 100 MB  
1024x768 resolution, 256 colors  
Disk Space:  
Display:  

与34931T相关器件

型号 品牌 描述 获取价格 数据表
34932A KEYSIGHT Multifunction Switch/Measure Unit

获取价格

34932T KEYSIGHT Multifunction Switch/Measure Unit

获取价格

34933A KEYSIGHT Multifunction Switch/Measure Unit

获取价格

34933T KEYSIGHT Multifunction Switch/Measure Unit

获取价格

349-5005-035 AMPHENOL Board Connector, 60 Contact(s), 12 Row(s), Male, Straight, Solder Terminal, LEAD FREE

获取价格

349-5005-054 AMPHENOL Board Connector, 60 Contact(s), 12 Row(s), Male, Straight, Solder Terminal,

获取价格