FUNCTIONAL DEVICE OPERATION  
OPERATIONAL MODES  
Description  
Set  
RXD short to high (recessive level)  
In Normal and Listen Only modes, if the RXD permanent recessive condition is detected  
RX-PR  
Reset  
Entering low power mode, the RXD recovery condition reached + P_SPI reading (Listen Only and Normal  
mode)  
Action  
Set the local failure flag, disable the CAN driver, set ERR low in Listen Only mode coming from Normal  
mode  
Description  
Set  
TXD permanent dominant  
In NORMAL modes, if TXD permanent dominant condition detected  
TX-PD  
Reset  
Entering low power mode, TXD recovery condition reached + P_SPI reading (Listen Only and Normal  
mode)  
Action  
Set the local failure flag, disable the CAN driver, set ERR low in Listen Only mode coming from Normal  
mode  
Description  
0 0 0: No CAN bus failure  
0 0 1:CANL short to GND  
0 1 0: CANL short to VDD  
0 1 1: CANL short to VBAT  
1 0 1: CANH short to GND  
1 1 0: CANH short to VDD  
1 1 1: CANH short to VSUP  
CANF (2,1,0)  
Set  
In Normal modes, if CAN failure condition detected  
Reset  
Entering low power mode, CAN failure recovery condition reached + P_SPI reading (Listen Only and  
Normal mode)  
Action  
Description  
Set  
Set the bus failure flag, set the ERR low in Normal mode after 4 Tx pulses  
VDD regulator reaches temperature prewarning  
In Normal mode or Listen Only mode, if the VDD temperature reaches the prewarning threshold  
Real time report, reset if the temperature falls below the prewarning threshold  
By default no action. If the ERR-EXT bit is set, ERR is set low.  
VSUP over-voltage detected  
VDD temp  
Reset  
Action  
Description  
Set  
In Normal and Listen Only modes, if the VSUP over-voltage threshold condition detected  
VSOV  
Reset  
Entering low power mode, VSUP over-voltage threshold condition recovered + P_SPI reading (Listen Only  
and Normal mode)  
Action  
By default no action. If the ERR-EXT bit is set, the ERR is set low.  
33902  
Analog Integrated Circuit Device Data  
Freescale Semiconductor  
25  

与33902相关器件

型号 品牌 描述 获取价格 数据表
339020A01F030 MOLEX Cable Assembly,

获取价格

33903 FREESCALE SBC Gen2 with CAN High Speed and LIN Interface

获取价格

33904 FREESCALE System Basis Chip Gen2 with High Speed CAN and LIN Interface

获取价格

33905 FREESCALE System Basis Chip Gen2 with High Speed CAN and LIN Interface

获取价格

3390-T144 SUMIDA General Power Transformer < Pin Type: EI Series>

获取价格

3390-T152 SUMIDA General Power Transformer < Pin Type: EI Series>

获取价格