259 PHM-SI
Vishay BCcomponents
www.vishay.com
Table 5
TEST PROCEDURES AND REQUIREMENTS
TEST
PROCEDURE
(quick reference)
REQUIREMENTS
NAME OF TEST
REFERENCE
IEC 60384-4 /
EN 130300
subclause 4.13
C/C: 15 %
ESR 1.3 x spec. limit
IL5 spec. limit
Endurance
Tamb = 105 C; UR applied; 3000 h
C/C: 30 %
ESR 3 x spec. limit
IL5 spec. limit
total failure percentage: 3 %
CECC 30301
T
amb = 105 C; UR and IR applied;
Useful life
subclause 1.8.1
3000 h
amb = 105 C; no voltage applied; 1000 h
C/C: 15 %
ESR 1.5 x spec. limit
IL5 spec. limit
T
Shelf life
IEC 60384-4 /
EN 130300
subclause 4.17
(storage at
after test: UR to be applied for 30 min,
24 h to 48 h before measurement
high temperature)
Statements about product lifetime are based on calculations and internal testing. They should only be interpreted as estimations. Also due to external factors, the
lifetime in the field application may deviate from the calculated lifetime. In general, nothing stated herein shall be construed as a guarantee of durability.
Revision: 05-Jun-2020
Document Number: 28441
8
For technical questions, contact: aluminumcaps2@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000