Solid-State Relays
AC Power Series Specifications
Opto 22 provides a full range of Power Series relays with a wide variety of voltage (120–575) and current options (3–45 amps). All
Power Series relays feature 4,000 volts of optical isolation and have a high PRV rating. Operating temperature is –40 °C to 100 °C.
Connection Diagram
120/240/380 Volt
NOTE: Model numbers ending in -17 are replacement parts only. Their specifications are identical
to the same model number without the -17. For example, 240D10-17 is identical to 240D10.
2
Model Nominal Nominal 1 cycle
Number AC Line Current Surge Signal Input
Nominal
Signal
Pick-up
Voltage
Signal
Drop-
out
Peak
Repetitive
Voltage
Maximum
Output
Voltage
Drop
Off-State Operating
Isolation
Voltage
Dissipation
(Watts/
Amp)
θ
jc*
(°C/Watt)
I t
Leakage
(mA)
Voltage
Range
Rating
t=8.3
(ms)
Voltage
Rating (Amps) Resistance
(Amps)
Peak
(Ohms)
Voltage Maximum
Maximum** (Volts AC)
120D3
120
3
85
1000
3VDC
(32V allowed)
1 VDC
1 VDC
1 VDC
1 VDC
1 VDC
1 VDC
1 VDC
1 VDC
1 VDC
1 VDC
1 VDC
1 VDC
1 VDC
10 VAC
10 VAC
10 VAC
10 VAC
10 VAC
600
600
600
600
600
600
600
600
600
600
600
800
800
600
600
600
600
600
1.6 volts
1.6 volts
1.6 volts
1.6 volts
1.6 volts
1.6 volts
1.6 volts
1.6 volts
1.6 volts
1.6 volts
1.6 volts
1.6 volts
1.6 volts
1.6 volts
1.6 volts
1.6 volts
1.6 volts
1.6 volts
2.5mA
7 mA
12–140
12–140
12–140
12–140
24–280
24–280
24–280
24–280
12–280
24–280
24–280
24–420
24–420
12–140
12–140
24–280
24–280
24–280
30
4,000V
4,000V
4,000V
11
1.3
1.2
0.67
11
1.7
1.6
1.3
0.9
1.7
1.6
1.6
1.3
1.3
0.9
0.9
1.3
0.9
1.6
1.3
1.6
1.3
0.9
RMS
RMS
RMS
RMS
RMS
RMS
RMS
RMS
RMS
RMS
RMS
RMS
RMS
RMS
RMS
RMS
RMS
RMS
rent Control varies with control voltage. See “Control
en1t2C0aDl1c0ulation” on page 17 for information.
120
10
110
1000
3VDC
(32V allowed)
50
120D25
120D45
240D3
120
120
240
240
240
240
240
240
240
380
380
120
120
240
240
240
25
45
3
250
650
85
1000
1000
1000
1000
730
3VDC
(32V allowed)
7 mA
250
3VDC
(32V allowed)
7 mA
1750 4,000V
3VDC
(32V allowed)
5 mA
30
50
4,000V
4,000V
4,000V
4,000V
4,000V
240D10
240Di10
240D25
240Di25
240D45
240Di45
380D25
380D45
120A10
120A25
240A10
240A25
240A45
10
10
25
25
45
45
25
45
10
25
10
25
45
110
110
250
250
650
650
250
650
110
250
110
250
650
3VDC
(32V allowed)
14 mA
14 mA
14 mA
14 mA
14 mA
14 mA
12 mA
12 mA
7 mA
1.3
1.3
1.2
1.2
0.67
0.67
1.2
0.67
1.3
1.2
1.3
1.2
0.67
3VDC
(32V allowed)
50
1000
730
3VDC
(32V allowed)
250
250
3VDC
(32V allowed)
1000
730
3VDC
(32V allowed)
1750 4,000V
1750 4,000V
3VDC
(32V allowed)
1000
1000
33K
3VDC
(32V allowed)
250
4,000V
3VDC
(32V allowed)
1750 4,000V
85VAC
(280V allowed)
50
250
50
4,000V
4,000V
4,000V
4,000V
33K
85VAC
(280V allowed)
7 mA
33K
85VAC
(280V allowed)
14 mA
14 mA
14 mA
33K
85VAC
(280V allowed)
250
33K
85VAC
1750 4,000V
(280V allowed)
Note: jc* = Thermal resistance from internal junction to base. Maximum internal junction temperature is 110 °C.
θ
** Operating Frequency: 25 to 65 Hz (operates at 400 Hz with 6 times the offstate leakage)
Connection Diagram, DC Power Series
*Control Current varies with control voltage. See “Control
Current Calculation” on page 17 for information.
Opto 22 • 43044 Business Park Drive • Temecula, CA 92590-3614 • www.opto22.com
PAGE
4
SALES 800-321-6786 • 951-695-3000 • FAX 951-695-3095 • sales@opto22.com • SUPPORT 800-835-6786 • 951-695-3080 • FAX 951-695-3017 • support@opto22.com
© 2006–2014 Opto 22. All rights reserved. Dimensions and specifications are subject to change. Brand or product names used herein are trademarks or registered trademarks of their respective companies or organizations.