IMX4 Series Data Sheet
4 Watt DC-DC Converters
®
Electrical Input Data
General conditions: TA = 25 °C, unless TC is specified.
Table 2: Input Data
Input
5IMX4
20IMX4
40IMX4
70IMX4
Unit
Characteristics
Conditions
min typ max min typ max min typ max min typ max
Vi
Input voltage range
TC min to TC max
Io = 0 to Io nom
4.7 5.0 16.8 8.4
36 16.8 2
75 40
100
121
150
VDC
Vi nom Nominal input voltage
5.0
20
40
70
Vi sur Repetitive surge voltage abs. max input (3 s)
--
40
tstart-up Converter start-uptime1 Worst case condition at
Vi min and full load
0.25 0.5
0.25 0.5
0.25 0.5
0.25 0.5
s
trise
Rise time 1
Vi nom
Io nom
resistive load
--
--
5
5
5
ms
capacitive load
12
12
12
Ii o
Ci
No-load input current
Input capacitance
Io = 0, Vi min to Vi max
--
15 20
0.54
3.7
5
10
60
5
10
30
mA
µF
--
0.3
4.2
400
0.15
5.6
3
Iinr p
fs
Inrush peak current
Switching frequency
Vi = Vi nom
3.8
400
--
A
Vi min to Vi max, Io = 0 to Io nom
400
100
A
400
kHz
mApp
Class
Ii rr
Reflected ripple current Io = 0 to Io nom
vi RFI Input RFI level
EN 55011/55022 4
--
A
A
conducted
1
Measured with a resistive or max. admissible capacitive load; see fig. 5
Operation at lower input voltage possible: Po approx. 80% of Po nom at Vi min = 14.4 V
Source impedance according to ETS 300132-2, version 4.3.
2
3
4
External capacitors required according to table 3.
Start-up
Filter to Comply with EN 55011/55022
Vo
Vo nom
trise
04008b
Electromagnetic emission requirements according to table
Electrical Input Data can be achieved by adding an external
capacitor as close as possible to the input terminals (see fig. 7
and table 3).
t
04035b
tstartup
Vi+
Fig. 5
Converter start-up and rise time
+
Ci
Inrush Current
Vi–
Fig. 7
The inrush current has been kept as low as possible by
choosing a very small input capacitance. A series resistor may
be inserted in the input line to further limit this current.
Input capacitors
04034a
A
Table 3: Input electrolytic capacitors
Model
20IMX4
40IMX4
70IMX4
3
2
Ci
100 µF
50 V
47 µF
100 V
330 µF
200 V
1
0
0
10
20
30
40
µs
Fig. 6
Typ. inrush current at Vi nom, Po nom versus time measured
according to ETS 300132-2, version 4.3 (40IMX4).
BCD20006-G Rev AC, 06-Jul-2012