ELECTRICAL CHARACTERISTICS
Rating at 25 °C ambient temperature unless otherwise specified
Nominal Zener
Voltage(3)
Maximum Reverse
Leakage Current
Maximum
Maximum
Maximum Zener Impedance(1)
Regulator Current Surge Current
Type No.
(2)
VZ @ IZT
(V)
IZT
ZZT @ IZT ZZK @ IZK
IZK
IR
@
VR
(V)
IRM
IZM
(mA)
(mA)
(mA)
(mA)
(W)
(W)
(mA)
1N4728AG
1N4729AG
1N4730AG
1N4731AG
1N4732AG
1N4733AG
1N4734AG
1N4735AG
1N4736AG
1N4737AG
1N4738AG
1N4739AG
1N4740AG
1N4741AG
1N4742AG
1N4743AG
1N4744AG
1N4745AG
1N4746AG
1N4747AG
1N4748AG
1N4749AG
1N4750AG
1N4751AG
1N4752AG
1N4753AG
1N4754AG
1N4755AG
1N4756AG
1N4757AG
1N4758AG
1N4759AG
1N4760AG
1N4761AG
1N4762AG
1N4763AG
1N4764AG
3.3
3.6
3.9
4.3
4.7
5.1
5.6
6.2
6.8
7.5
8.2
9.1
10
11
12
13
15
16
18
20
22
24
27
30
33
36
39
43
47
51
56
62
68
75
82
91
100
76.0
69.0
64.0
58.0
53.0
49.0
45.0
41.0
37.0
34.0
31.0
28.0
25.0
23.0
21.0
19.0
17.0
15.5
14.0
12.5
11.5
10.5
9.5
10
10
400
400
1.0
100
100
50
1.0
1.0
276
252
234
217
193
178
162
146
133
121
110
100
91
1380
1260
1190
1070
970
890
810
730
660
605
550
500
454
414
380
344
305
285
250
225
205
190
170
150
135
125
115
110
95
1.0
9.0
9.0
8.0
7.0
5.0
2.0
3.5
4.0
4.5
5.0
7.0
8.0
9.0
10
400
1.0
1.0
400
1.0
10
1.0
500
1.0
10
1.0
550
1.0
10
1.0
600
1.0
10
2.0
700
1.0
10
3.0
700
1.0
10
4.0
700
0.5
10
5.0
700
0.5
10
6.0
700
0.5
10
7.0
700
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
10
7.6
700
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
8.4
83
700
9.1
76
700
9.9
69
14
700
11.4
12.2
13.7
15.2
16.7
18.2
20.6
22.8
25.1
27.4
29.7
32.7
35.8
38.8
42.6
47.1
51.7
56.0
62.2
69.2
76.0
61
16
700
57
20
750
50
22
750
45
23
750
41
25
750
38
35
750
34
8.5
40
1000
1000
1000
1000
1500
1500
1500
2000
2000
2000
2000
3000
3000
3000
30
7.5
45
27
7.0
50
25
6.5
60
23
6.0
70
22
5.5
80
19
5.0
95
18
90
4.5
110
125
150
175
200
250
350
16
80
4.0
14
70
3.7
13
65
3.3
12
60
3.0
11
55
2.8
10
50
2.5
9.0
45
Notes:
(1) The Zener impedance is derived from the 1kHZ AC voltage which results when an AC current having an RMS value equal
to 10% of the Zener current (IZT or IZK) is superimposed on IZT or IZK. Zener impedance is measured at two points to
insure a sharp knee on the breakdown curve and to eliminate unstable units
(2) Valid provided that electrodes at a distance of 10mm from case are kept at ambient temperature
(3) Measured under thermal equilibrium and DC test conditions.
(4) Standard Zener voltage tolerance is ± 5% tolerance. Other Zener voltages and tolerances are available upon request.
Page 2 of 2
Rev. 03 : March 25, 2005