1N3879(R), 1N3889(R), 6/ 12/ 16FL(R) Series
ELECTRICAL SPECIFICATIONS
Voltage Ratings
Voltage
VRRM max. repetitive
VRSM , maximum non- IRRM max. IRRM max. IRRM max.
Type number
Code peak and off-state voltage repetitive peak voltage TJ = 25°C TJ = 100°C TJ = 150°C
V
V
µA
mA
mA
1N3879.
1N3880.
1N3881.
1N3882.
1N3883.
1N3889.
1N3890.
1N3891.
1N3892.
1N3893.
50
75
100
200
300
400
50
100
200
300
400
150
250
350
450
75
150
250
350
450
-
15 *
1.0 *
3.0 *
-
-
-
-
-
25 *
3.0 *
5.0 *
12
5
50
100
200
400
600
800
1000
75
150
275
500
725
950
1250
10
20
40
60
80
100
6FL..
12FL..
16FL..
50
-
6.0
Forward Conduction
1N3879.
1N3889.
Parameter
1N3883. 6FL.. 1N3893. 16FL.. Units Conditions
12FL..
IF(AV) Max. average forward current
@ TC = 100°C
180° conduction, half sine wave.
DC
6*
6
12 *
16
A
A
IF(RMS) Max. RMS current
9.5
85
9.5
130
135
110
115
86
19
170
180
145
150 *
145
25
IFSM
Max. peak, one-cycle
215
225
180
190
230
210
160
150
t = 10ms No voltage
t = 8.3ms reapplied
t = 10ms 100% VRRM
non-repetitive forward current
90
A
72
2222222222222
75 *
36
t = 8.3ms reapplied
Sinusoidal half wave
I2t
Maximum I2t for fusing
t = 10ms No voltage Initial TJ = 150°C
t = 8.3ms reapplied
33
78
130
A2s
26
23
60
55
103
94
t = 10ms 100% VRRM
t = 8.3ms reapplied
I2√t
Maximum I2√t for fusing
363
1.4 *
1.5 *
856
1.4
1.5
1452
1.4 *
1.5 *
2290 A2√s t = 0.1 to 10ms, no voltage reapplied
VFM
Max. forward voltage
1.4
1.5
TJ = 25°C, IF = rated IF(AV) (D.C.)
V
TC = 100°C, IFM = π x rated IF(AV)
*JEDECregisteredvalue
2